Technical Information
Item condition |
New |
Manufacture name |
Switch actuator REG-K/2x230/16 w. manual mode and current detection, light grey |
Brand |
Schneider Electric
|
Categories |
Sensors
|
Country of origin |
DE |
Harmonized System Code |
8537 1098 99
|
Mounting method |
DRA (DIN-rail adapter) |
Rated current |
16 A |
Output power |
3600 W |
Rated operating voltage |
230 V |
Bus system KNX |
Yes |
Bus system radio frequent |
No |
Bus system Powernet |
No |
Max. switching power |
3600 W |
With bus connection |
Yes |
Max. number of switching contacts |
2 |
Number of digital inputs |
0 |
Width in number of modular spacings |
2.5 |
Max. switching current |
16 A |
Bus system LON |
No |
Suitable for C-load |
Yes |
Different phases connectable |
Yes |
Local operation/hand operation |
Yes |
Degree of protection (IP) |
IP20 |
With LED indication |
No |
Modular expandability |
No |
Bus system KNX radio |
No |
Radio frequent bidirectional |
No |
Bus module detachable |
No |
Min. depth of built-in installation box |
0 mm |
Max. switching power LED |
0 W |
Packing details
Packing level 1 |
3606485100050 |
Packing level 2 |
3606485100058 |
Downloads
Description
For independent switching of loads via make contacts. The actuator has integrated current detection that measures the load current on each channel. All 230 V switch outputs can be operated with manual switches. With integrated bus coupling unit. A green LED indicates that the device is ready for operation once the application has been loaded. The load is connected with screw terminals. For installation on DIN rails TH35 according to EN 60715. The bus is connected using a bus connecting terminal. a data rail is not necessary. Operation as break contact or make contact. Staircase lighting function with/without manual OFF function and switch-off warning. Delay functions. Scenes. Logic function. Blocking or priority control. Feedback function. Status. Central function with delay. Parameterisation for bus voltage failure and recovery. Behaviour for download. Current detection function: Behaviour when value exceeds/falls short of the threshold value. Energy, operating and switch on counter with limit value monitoring. Flash function. Nominal voltage: 230 V AC, 50-60 Hz. DC 12-24 V ±10%, 0.1-16 A. For each switching contact: Switching current: 16 A, cos Phi 0.6. AC1 operation: max. 16 A. AC3 operation: max. 10 A. AC5 operation: max. 16 A. DC current switching capacity: max. 16 A/ 24 V DC. Output life endurance: Mechanical: 1000000. AC1/AC3/AC5 operation: 3x10000. 230V, 1A resistive: 8x100000. Incandescent lamps: 230 V AC, max. 3600 W. Halogen lamps: 230 V AC, max. 2500 W. Fluorescent lamps: 230 V AC, max. 2500 VA, with parallel compensation. Capacitive load: 230 V AC, 16 A, max. 200 µF. Minimum switching performance: 100 mA/12 V AC/DC. Maximum peak inrush-current: 150µs: 600 A. 250µs: 480 A. 600µs: 300 A. Current detection load current: Detection range: 0.1 A to 16 A (sine effective value or direct current). Detection accuracy: +/- 8% of the present current value (sine) and +/- 100 mA. Frequency: 50/60 Hz with alternating voltage. Display: 100 mA. Device width: 2.5 modules, approx. 45 mm. Contents: With bus connecting terminal and cable cover. Colour: light grey. 2 channel device