Register to unlock your exclusive B2B prices and start shopping. Sign up now!
SX inverter IP54, 200 kW, 3~ 690 VAC, V/f drive, built-in filter, max. AA055840F image 1
SX inverter IP54, 200 kW, 3~ 690 VAC, V/f drive, built-in filter, max. AA055840F image 2
SX inverter IP54, 200 kW, 3~ 690 VAC, V/f drive, built-in filter, max. AA055840F image 3
SX inverter IP54, 200 kW, 3~ 690 VAC, V/f drive, built-in filter, max. AA055840F image 4
SX inverter IP54, 200 kW, 3~ 690 VAC, V/f drive, built-in filter, max. AA055840F thumbnail 1
SX inverter IP54, 200 kW, 3~ 690 VAC, V/f drive, built-in filter, max. AA055840F thumbnail 2
SX inverter IP54, 200 kW, 3~ 690 VAC, V/f drive, built-in filter, max. AA055840F thumbnail 3
SX inverter IP54, 200 kW, 3~ 690 VAC, V/f drive, built-in filter, max. AA055840F thumbnail 4

SX inverter IP54, 200 kW, 3~ 690 VAC, V/f drive, built-in filter, max. AA055840F

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
28 004,66 €
This price is valid until 24.12.24
EAN: 4549734991216
MPN: SX-D6200-EVA4
Package: 1

Technical Information

Item condition New
Manufacture name SX inverter IP54, 200 kW, 3~ 690 VAC, V/f drive, built-in filter, max. AA055840F
Brand Omron
Categories Control gear
Country of origin NL
Number of digital inputs 8
Number of digital outputs 5
Number of analogue inputs 4
Number of analogue outputs 2
Supporting protocol for LON No
Number of HW-interfaces industrial Ethernet 0
Number of HW-interfaces RS-232 0
Number of HW-interfaces RS-422 0
Number of HW-interfaces RS-485 0
Number of HW-interfaces serial TTY 0
Number of HW-interfaces USB 0
Number of HW-interfaces parallel 0
Number of HW-interfaces other 3
With optical interface No
Supporting protocol for TCP/IP Yes
Supporting protocol for ASI No
Supporting protocol for PROFIBUS Yes
Supporting protocol for CAN No
Supporting protocol for INTERBUS No
Supporting protocol for KNX No
Supporting protocol for Modbus Yes
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet Yes
Supporting protocol for SUCONET No
Supporting protocol for other bus systems Yes
Degree of protection (IP) IP54
Supporting protocol for SERCOS No
Supporting protocol for INTERBUS-Safety No
Mains voltage 500-690 V
Mains frequency 50/60 Hz
Number of interfaces PROFINET 0
Type of converter Other
Number of phases output 3
Number of phases input 3
Integrated breaking resistance No
Application in industrial area permitted Yes
Max. output frequency 400 Hz
Max. output at linear load at rated output voltage 160 kW
Max. output at quadratic load at rated output voltage 200 kW
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for EtherNet/IP Yes
Supporting protocol for Foundation Fieldbus No
Supporting protocol for PROFINET CBA No
Supporting protocol for PROFINET IO Yes
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Max. output voltage 690 V
Nominal output current I2N 200 A
Degree of protection (NEMA) Other

Packing details

Packing level 1 4549734991216, 4549734991216

Downloads

Description

SX inverter IP54, 200 kW, 3~ 690 VAC, V/f drive, built-in filter, max. output freq. 400 Hz