Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Type 1+2+3 combined arrester DEHNshield ZP Basic 2 LSG for TT and TN-S image 1
Type 1+2+3 combined arrester DEHNshield ZP Basic 2 LSG for TT and TN-S image 2
Type 1+2+3 combined arrester DEHNshield ZP Basic 2 LSG for TT and TN-S image 3
Type 1+2+3 combined arrester DEHNshield ZP Basic 2 LSG for TT and TN-S thumbnail 1
Type 1+2+3 combined arrester DEHNshield ZP Basic 2 LSG for TT and TN-S thumbnail 2
Type 1+2+3 combined arrester DEHNshield ZP Basic 2 LSG for TT and TN-S thumbnail 3

Type 1+2+3 combined arrester DEHNshield ZP Basic 2 LSG for TT and TN-S

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
434,72 €
This price is valid until 31.12.24
EAN: 4013364449725
MPN: 909731
Package: 1

Technical Information

Item condition New
Manufacture name Type 1+2+3 combined arrester DEHNshield ZP Basic 2 LSG for TT and TN-S
Brand Dehn
Categories Lighting protection
Country of origin DE
Harmonized System Code 8536 3090 00
Mounting method Busbar
Lightning impulse current (10/350 µs) 30 kA
Number of poles 4
Construction size 3 modular spacing
Follow current extinguishing capability 25 kA
Max. continuous voltage AC 255 V
Nominal voltage AC 230 V
Test class Type 1 and 2 and 3
Voltage protection level L-N 1.5 kV
Signalling at the device Optic
Degree of protection (IP) IP30
Voltage protection level N-PE 1.5 kV
Max. conductor cross section solid (solid, stranded) 35 mm²
Max. conductor cross section flexible (fine-strand) 25 mm²
Specific energy (W/R) 14.06 kJ/Ohm
Energy-coordinated protection effect with regard to the terminal equipment Yes
System configuration TN-S Yes
System configuration TT Yes
Max. overcurrent protection device, parallel connection (fuse) 160 A
Max. overcurrent protection device, series connection (fuse) 160 A
Voltage switching spark gap technology Yes

Packing details

Packing level 1 4013364449725, 4013364449725

Downloads

Description

Type 1 + type 2 + type 3 combined arrester for TT and TN-S systems (3+1 configuration). Subsequent integration of a single-pole B6 circuit breaker for supplying the intelligent measuring system possible. Two sockets for the 230 V power supply (N and L) for the compartment for additional applications / termination point meter mounting board according to VDE-AR-N 4100 are integrated in the device; for use on the 40 mm busbar system in the main power supply system according to IEC 60634-4-44 clause 443 of buildings without external lightning protection system (also with overhead line supply).