Type1+2+3 combined arrester DEHNshield ZP 2 SG for TNC systems image 1
Type1+2+3 combined arrester DEHNshield ZP 2 SG for TNC systems image 2
Type1+2+3 combined arrester DEHNshield ZP 2 SG for TNC systems image 3

Type1+2+3 combined arrester DEHNshield ZP 2 SG for TNC systems

In stock price (excl. VAT):
552,51 €
This price is valid until 2024-12-31
Price per m: 552,51 €
EAN: 4013364424692
MPN: 909630
Our warehouse: No Vendor stock: No
Per package: 1 Per box: 1 Per pallet: N/A
Technical data
Item condition New
Manufacture name Type1+2+3 combined arrester DEHNshield ZP 2 SG for TNC systems
Brand Dehn
Categories Lighting protection
Country of origin DE
Harmonized System Code 8536 3090 00
Mounting method Busbar
Lightning impulse current (10/350 µs) 37.5 kA
Number of poles 3
Voltage protection level 1.5 kV
Follow current extinguishing capability 25 kA
Max. continuous voltage AC 255 V
Nominal voltage AC 230 V
Test class Type 1 and 2 and 3
Signalling at the device Optic
Degree of protection (IP) IP30
Max. conductor cross section solid (solid, stranded) 25 mm²
Specific energy (W/R) 39.06 kJ/Ohm
Energy-coordinated protection effect with regard to the terminal equipment Yes
System configuration TN-C Yes
System configuration TN-S No
System configuration TT No
System configuration TN-C-S No
Max. overcurrent protection device, parallel connection (fuse) 160 A
Max. overcurrent protection device, series connection (fuse) 160 A
Voltage switching spark gap technology Yes
Overcurrent protected voltage tapping Yes
Packing details
Packing level 1 4013364424692, 4013364424692
Downloads
Description
Tested type 1 + type 2 + type 3 combined arrester according to IEC 61643-11 for TN-C systems (3+0 configuration) including overcurrent-protected 230 V power supply (N and L) including spare fuse for the compartment for additional applications / termination point meter mounting board according to VDE-AR-N 4100; can be installed completely without tools thanks to click + power connection method for 40 mm busbar systems and push-in earthing terminal; for use in the main power supply system according to IEC 60634-4-44 clause 443 of buildings with an external lightning protection system (class of LPS III/IV). A suitable cover clip according to DIN VDE 0603-1 for every standard meter panel and 2 x socket and 2 x plug (without connecting cables) for wiring the intelligent measuring system according to VDE-AR 4100 are included in delivery.

Accessories