Item condition |
New |
Manufacture name |
Limit value monitoring, Input: single-phase voltage, Relay output, Inp |
Brand |
Weidmüller
|
Categories |
Sensors
|
Country of origin |
CN |
Harmonized System Code |
8543 7090 00
|
Width |
22.5 mm |
Height |
117 mm |
Depth |
114.3 mm |
Power consumption |
3 W |
Switching voltage |
250 V |
Type of electric connection |
Spring clamp connection |
Degree of protection (IP) |
IP20 |
Number of input ranges +10 V ... -10 V |
0 |
Number of input ranges +5 V ... -5 V |
0 |
Number of input ranges 0 V ... 1 V |
0 |
Number of input ranges 0 mA ... 10 mA |
0 |
Number of input ranges 0 mV ... 100 mV |
0 |
Number of input ranges 0 V ... 2 V |
0 |
Number of input ranges 0 V ... 2.5 V |
0 |
Number of input ranges 0 mA ... 20 mA |
0 |
Number of input ranges 0 V ... 20 V |
0 |
Number of input ranges 0 mV ... 200 mV |
0 |
Number of input ranges 0 V ... 24 V |
0 |
Number of input ranges 0 V ... 30 V |
0 |
Number of input ranges 0 mV ... 300 mV |
0 |
Number of input ranges 0 mA ... 5 mA |
0 |
Number of input ranges 0 V ... 5 V |
0 |
Number of input ranges 0 mV ... 500 mV |
0 |
Number of input ranges 0 mV ... 60 mV |
0 |
Number of input ranges -1 V ... +1 V |
0 |
Number of input ranges 1 V ... 5 V |
0 |
Number of input ranges -10 mA ... +10 mA |
0 |
Number of input ranges -10 V ... +10 V |
0 |
Number of input ranges 10 V ... 0 V |
0 |
Number of input ranges 10 V ... 2 V |
0 |
Number of input ranges -100 mV ... +100 mV |
0 |
Number of input ranges -2 V ... +2 V |
0 |
Number of input ranges 2 V ... 10 V |
0 |
Number of input ranges -2.5 V ... +2.5 V |
0 |
Number of input ranges -20 mA ... +20 mA |
0 |
Number of input ranges -20 V ... +20 V |
0 |
Number of input ranges 20 mA ... 0 mA |
0 |
Number of input ranges 20 mA ... 4 mA |
0 |
Number of input ranges -300 mV ... +300 mV |
0 |
Number of input ranges 4 mA ... 20 mA |
0 |
Number of input ranges -5 mA ... +5 mA |
0 |
Number of input ranges -5 V ... +5 V |
0 |
Number of input ranges 5 V ... 0 V |
0 |
Number of input ranges 5 V ... 1 V |
0 |
Number of input ranges -500 mV ... +500 mV |
0 |
Number of input ranges -60 mV ... +60 mV |
0 |
Number of limit values |
2 |
Number of output circuits relays normally open contact |
2 |
Number of output circuits relays change-over contact |
2 |
Number of output circuits transistor potential-free |
0 |
Rated operation frequency |
0-50 Hz |
Rated supply voltage at AC |
0 V |
Rated supply voltage at DC |
0 V |
Inherently safe according to EN 60947-5-6 NAMUR |
No |
Primary voltage tolerance |
5 % |
Galvanic separation between input and output |
Yes |
Construction type of device |
Field device |
SIL according to IEC 61508 |
None |
Degree of protection (NEMA) |
1 |