Register to unlock your exclusive B2B prices. Register now
MD01 image 1
Acti9 iC60 RCBO - 3P - 32 A - C Curve - 10000A/15kA - 30 mA - A type image 2
Acti9 iC60 RCBO - 3P - 32 A - C Curve - 10000A/15kA - 30 mA - A type image 3
Acti9 iC60 RCBO - 3P - 32 A - C Curve - 10000A/15kA - 30 mA - A type image 4

Acti9 iC60 RCBO - 3P - 32 A - C Curve - 10000A/15kA - 30 mA - A type

In stock price (excl. VAT):
190,81 €
This price is valid until 2024-12-24
Price per m: 190,81 €
EAN: 3606481157973
MPN: A9D17332
Our warehouse: No Vendor stock: No
Per package: 1 Per box: 4 Per pallet: N/A
Technical data
Item condition New
Brand Schneider Electric
Categories Leakage protection
Harmonized System Code 8536 2010 90
Voltage type AC
Built-in depth 45 mm
Rated current 32 A
Rated voltage 400 V
Release characteristic C
Rated insulation voltage Ui 500 V
Rated fault current 0.03 A
Leakage current type A
Surge current capacity 0.25 kA
Current limiting class 1
Over voltage category 3
Pollution degree 2
Width in number of modular spacings 3
Frequency 50 Hz
Degree of protection (IP) IP20
Number of protected poles 3
Concurrently switching neutral conductor Yes
Rated short-circuit breaking capacity according to IEC 60947-2 15 kA
Connectable conductor cross section solid-core 1-35 mm²
Connectable conductor cross section multi-wired 1-25 mm²
With interlocking device No
Ambient temperature during operating -25-40 °C
Flush-mounted installation No
Number of poles (total) 3
Anti-nuisance tripping version No
Rated impulse withstand voltage Uimp 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1 0 kA
Disconnection characteristic Undelayed
Rated short-circuit breaking capacity according to EN 61009 0 kA
Packing details
Packing level 1 3606481157973
Packing level 2 3606481157970
Packing level 3 3606481157971
Downloads
Description
This Acti9 iC60 RCBO is a modular and reliable residual current breaker with overcurrent protection (RCBO). It is a 3P RCBO with 3 protected poles, rated current is 32A, and operating voltage is 220VAC to 240VAC. Breaking capacity at 220VAC to 240VAC is 10kA according to EN/IEC 61009-2-1. Breaking capacity at 220VAC to 240VAC is 15kA according to EN/IEC 60947-2. Electrical endurance goes up to 10000 cycles, and mechanical endurance goes up to 20000 cycles. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. Device location in system is outgoer, and the earth leakage protection class is type A. This product is compliant with EN/IEC 60947-2 and EN/IEC 61009-2-1.