Item condition |
New |
Manufacture name |
Advanced control unit, TeSys Ultra, 3-12A, 1P motors, protection & diagnostic, class 10, coil 110-240V AC/DC |
Brand |
Schneider Electric
|
Categories |
Modular switches
|
Country of origin |
FR |
Harmonized System Code |
8537 1098 99
|
Width |
45 mm |
Height |
66 mm |
Depth |
60 mm |
With transformer |
No |
Rated operation power at AC-3, 400 V |
2.2 kW |
Number of command positions |
0 |
Number of auxiliary contacts as normally open contact |
0 |
Number of auxiliary contacts as normally closed contact |
0 |
Suitable for emergency stop |
No |
Rated operation current Ie |
3 A |
Number of indicator lights |
0 |
Overload release current setting |
3-12 A |
Supporting protocol for LON |
No |
Supporting protocol for TCP/IP |
No |
Supporting protocol for ASI |
No |
Supporting protocol for PROFIBUS |
No |
Supporting protocol for CAN |
No |
Supporting protocol for INTERBUS |
No |
Supporting protocol for Modbus |
No |
Supporting protocol for Data-Highway |
No |
Supporting protocol for DeviceNet |
No |
Supporting protocol for SUCONET |
No |
Supporting protocol for other bus systems |
No |
External reset possible |
No |
Rail mounting possible |
Yes |
Rated control supply voltage at AC 50 Hz |
110-240 V |
Rated control supply voltage at AC 60 Hz |
110-240 V |
Rated control supply voltage at DC |
110-220 V |
Degree of protection (IP) |
IP40 |
Supporting protocol for SERCOS |
No |
Supporting protocol for INTERBUS-Safety |
No |
Release class |
CLASS 10 |
With short-circuit release |
Yes |
With fuse |
No |
Type of electrical connection of main circuit |
Screw connection |
Type of electrical connection for auxiliary- and control current circuit |
Screw connection |
Supporting protocol for AS-Interface Safety at Work |
No |
Supporting protocol for DeviceNet Safety |
No |
Supporting protocol for EtherNet/IP |
No |
Supporting protocol for Foundation Fieldbus |
No |
Supporting protocol for PROFINET CBA |
No |
Supporting protocol for PROFINET IO |
No |
Supporting protocol for PROFIsafe |
No |
Supporting protocol for SafetyBUS p |
No |
Voltage type for actuating |
AC/DC |
Type of motor starter |
Other |
Rated operation power at AC-3, 230 V, 3-phase |
0 kW |
Rated power, 460 V, 60 Hz, 3-phase |
0 kW |
Rated power, 575 V, 60 Hz, 3-phase |
0 kW |
Rated operation current at AC-3, 400 V |
12 A |
Ambient temperature, upper operating limit |
70 °C |
Temperature compensated overload protection |
Yes |
Rated conditional short-circuit current, type 2, 400 V |
12 A |
Rated conditional short-circuit current, type 2, 230 V |
3 A |
Rated conditional short-circuit current, type 1, 480 Y/277 V |
3 A |
Rated conditional short-circuit current, type 1, 600 Y/347 V |
12 A |
Degree of protection (NEMA) |
Other |
Coordination class according to IEC 60947-4-3 |
Class 2 |