Register to unlock your exclusive B2B prices. Register now
Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A image 1
Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A image 2
Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A image 3
Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A image 4
Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A image 5
Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A image 6
Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A image 7
Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A image 8
Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A image 9
Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A image 10
Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A image 11
Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A image 12
Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A image 13
Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A image 14
Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A image 15
Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A image 16

Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A

In stock price (excl. VAT):
168,16 €
This price is valid until 2024-12-31
Price per m: 168,16 €
EAN: 4015081822140
MPN: 187165
Our warehouse: No Vendor stock: No
Per package: 1 Per box: 40 Per pallet: N/A
Technical data
Item condition New
Manufacture name Arc Fault Detection Device, 2p, B, 10 A, 10 mA, type A
Brand EATON
Categories Leakage protection
Country of origin CZ
Harmonized System Code 8536 3010 00
Frequency 50 Hz
Built-in depth 67 mm
Rated current 10 A
Rated voltage 230 V
Release characteristic B
Number of poles 2
Rated fault current 0.01 A
Leakage current type A
Current limiting class 3
Over voltage category 3
Pollution degree 2
Width in number of modular spacings 3
Degree of protection (IP) IP20
Concurrently switching neutral conductor No
Rated short-circuit breaking capacity according to IEC 60947-2 0 kA
Rated switch current auxiliary device 0 A
Rated voltage auxiliary device 230 V
Control voltage type auxiliary equipment AC
Additional equipment attached at delivery Fire protection switch
Rated short-circuit breaking capacity according to EN 61009 10 kA
Packing details
Packing level 1 4015081822140
Packing level 2 9008790841125
Description
High-quality arc fault detection device (AFDD) with residual current device/miniature circuit breaker combination, line voltage-independent, contact position indicator red - green, terminal rear plug protection, tri-stable slide catch - enables removal from existing busbar system, comprehensive range of accessories suitable for subsequent installation, wide range of rated fault currents, rated operational currents up to 40 A, tripping characteristics B, C, D, rated breaking capacity 10 kA, suitable for outdoor use (on-site power and outdoor distribution board) up to -25 °C