Register to unlock your exclusive B2B prices and start shopping. Sign up now!
circuit breaker ComPact NS800L, 150 kA at 415 VAC, Micrologic 2.0 trip unit, 800 A, fixed, 3 poles 3d image 1
MD01 image 2
circuit breaker ComPact NS800L, 150 kA at 415 VAC, Micrologic 2.0 trip unit, 800 A, fixed, 3 poles 3d image 3
circuit breaker ComPact NS800L, 150 kA at 415 VAC, Micrologic 2.0 trip unit, 800 A, fixed, 3 poles 3d image 4
circuit breaker ComPact NS800L, 150 kA at 415 VAC, Micrologic 2.0 trip unit, 800 A, fixed, 3 poles 3d image 5
circuit breaker ComPact NS800L, 150 kA at 415 VAC, Micrologic 2.0 trip unit, 800 A, fixed, 3 poles 3d thumbnail 1
MD01 thumbnail 2
circuit breaker ComPact NS800L, 150 kA at 415 VAC, Micrologic 2.0 trip unit, 800 A, fixed, 3 poles 3d thumbnail 3
circuit breaker ComPact NS800L, 150 kA at 415 VAC, Micrologic 2.0 trip unit, 800 A, fixed, 3 poles 3d thumbnail 4
circuit breaker ComPact NS800L, 150 kA at 415 VAC, Micrologic 2.0 trip unit, 800 A, fixed, 3 poles 3d thumbnail 5

circuit breaker ComPact NS800L, 150 kA at 415 VAC, Micrologic 2.0 trip unit, 800 A, fixed, 3 poles 3d

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
2 402,20 €
This price is valid until 14.02.25
EAN: 3303430334682
MPN: 33468
Package: 1

Technical Information

Item condition New
Manufacture name circuit breaker ComPact NS800L, 150 kA at 415 VAC, Micrologic 2.0 trip unit, 800 A, fixed, 3 poles 3d
Brand Schneider Electric
Categories Breakers
Country of origin IT
Harmonized System Code 8536 2090 90
Number of auxiliary contacts as normally open contact 0
Number of auxiliary contacts as normally closed contact 0
Rated permanent current Iu 800 A
With integrated under voltage release No
Number of poles 3
Overload release current setting 320-800 A
Number of auxiliary contacts as change-over contact 0
Rated voltage 690 V
Degree of protection (IP) IP40
Position of connection for main current circuit Front side
Motor drive integrated No
Type of electrical connection of main circuit Screw connection
Type of control element Toggle
With switched-off indicator Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz 150 kA
Adjustment range undelayed short-circuit release 1200-8000 A
Suitable for DIN rail (top hat rail) mounting No
Integrated earth fault protection Yes
Motor drive optional Yes
Device construction Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional No
Complete device with protection unit Yes

Packing details

Packing level 1 3303430334682

Downloads