Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Control Unit for F3SJ, 3NO + 1NC, (use F39-JC_B double ended cable) F3SP6001R image 1
Control Unit for F3SJ, 3NO + 1NC, (use F39-JC_B double ended cable) F3SP6001R image 2
Control Unit for F3SJ, 3NO + 1NC, (use F39-JC_B double ended cable) F3SP6001R image 3
Control Unit for F3SJ, 3NO + 1NC, (use F39-JC_B double ended cable) F3SP6001R thumbnail 1
Control Unit for F3SJ, 3NO + 1NC, (use F39-JC_B double ended cable) F3SP6001R thumbnail 2
Control Unit for F3SJ, 3NO + 1NC, (use F39-JC_B double ended cable) F3SP6001R thumbnail 3

Control Unit for F3SJ, 3NO + 1NC, (use F39-JC_B double ended cable) F3SP6001R

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
344,59 €
This price is valid until 31.01.25
EAN: 4547648813402
MPN: F3SP-B1P
Package: 1

Technical Information

Item condition New
Manufacture name Control Unit for F3SJ, 3NO + 1NC, (use F39-JC_B double ended cable) F3SP6001R
Brand Omron
Categories Relays
Country of origin NL
Harmonized System Code 8536 4900 00
Width 45 mm
Model Other
Height 76 mm
Depth 111 mm
With approval according to UL Yes
With detachable clamps No
With start input No
With feedback circuit No
Number of outputs, safety related, undelayed, with contact 0
Number of outputs, safety related, delayed, with contact 0
Number of outputs, safety related, undelayed, semiconductors 0
Number of outputs, safety related, delayed, semiconductors 0
Number of outputs, signalling function, undelayed, with contact 4
Number of outputs, signalling function, delayed, with contact 0
Number of outputs, signalling function, undelayed, semiconductors 0
Number of outputs, signalling function, delayed, semiconductors 0
Type of electric connection Screw connection
Rail mounting possible Yes
With muting function Yes
Type of safety according to IEC 61496-1 1
With approval for BG BIA Yes
Suitable for monitoring of magnetic switches Yes
Suitable for monitoring of proximity switches Yes
Suitable for monitoring of emergency-stop circuits Yes
Suitable for monitoring of optoelectronic protection equipment Yes
Suitable for monitoring of position switches Yes
Suitable for monitoring of tactile sensors Yes
Suitable for monitoring of valves Yes
Performance level according to EN ISO 13849-1 Level a
Stop category according to IEC 60204 0 (zero)
Voltage type for actuating AC
Evaluation inputs Other
SIL according to IEC 61508 None
With approval for TÜV No

Packing details

Packing level 1 4547648813402, 4547648813402

Downloads

Description

Control Unit for F3SJ, 3NO + 1NC, (use F39-JC_B double ended cable)