Item condition |
New |
Manufacture name |
Counter module, 4 digital inputs +24 V , 4 digital outputs, +24 V/ 2A, 1 incremental encoder input (RS422 or TTL) up to 125 kHz, 16 bits |
Brand |
EATON
|
Categories |
Programmable logic controllers
|
Country of origin |
AT |
Harmonized System Code |
8538 9099 00
|
Width |
80.3 mm |
Height |
16.8 mm |
Depth |
104.2 mm |
Frequency measurement |
Yes |
Suitable for safety functions |
No |
Voltage type of supply voltage |
DC |
Supporting protocol for LON |
No |
Number of HW-interfaces industrial Ethernet |
0 |
Number of HW-interfaces RS-232 |
0 |
Number of HW-interfaces RS-422 |
0 |
Number of HW-interfaces RS-485 |
0 |
Number of HW-interfaces serial TTY |
0 |
Number of HW-interfaces USB |
0 |
Number of HW-interfaces parallel |
0 |
Number of HW-interfaces other |
1 |
With optical interface |
No |
Supporting protocol for TCP/IP |
No |
Supporting protocol for ASI |
No |
Supporting protocol for PROFIBUS |
No |
Supporting protocol for CAN |
No |
Supporting protocol for INTERBUS |
No |
Supporting protocol for KNX |
No |
Supporting protocol for Modbus |
No |
Supporting protocol for Data-Highway |
No |
Supporting protocol for DeviceNet |
No |
Supporting protocol for SUCONET |
No |
Supporting protocol for other bus systems |
Yes |
Number of functions |
0 |
Suitable for counting |
Yes |
Suitable for weighing |
No |
Suitable for welding control |
No |
Suitable for pressure control |
No |
Suitable for NC |
No |
Suitable for SSI |
No |
Suitable for electronic positioning |
Yes |
Suitable for CNC |
No |
Suitable for incremental data detection |
Yes |
Suitable for detection absolute value |
No |
Suitable for flux controller |
Yes |
Suitable for flux measurement |
Yes |
Suitable for path controller |
No |
Suitable for cam controller |
No |
Suitable for flying saw |
No |
Suitable for multi-axis control |
No |
Suitable for single-axis controller |
Yes |
Suitable for multi-axis positioning |
No |
Suitable for single-axis positioning |
Yes |
Rail mounting possible |
Yes |
Explosion safety category for gas |
None |
Explosion safety category for dust |
None |
Fieldbus connection over separate bus coupler possible |
Yes |
System accessory |
Yes |
Appendant operation agent (Ex ia) |
No |
Appendant operation agent (Ex ib) |
No |
Degree of protection (IP) |
IP20 |
Supporting protocol for SERCOS |
No |
Supporting protocol for INTERBUS-Safety |
No |
Number of interfaces PROFINET |
0 |
Number of HW-interfaces Wireless |
0 |
Front built-in possible |
No |
Rack-assembly possible |
No |
Wall mounting/direct mounting |
No |
Radio standard Bluetooth |
No |
Radio standard Wi-Fi 802.11 |
No |
Function block automatic reset |
No |
Function block contactless working protection installation |
No |
Function block operating mode selection |
No |
Function block emergency stop |
No |
Function block restart blockage |
No |
Function block access control |
No |
Function block affirm pushbutton |
No |
Function block 2-hand switching |
No |
IO link master |
No |
Performance level according to EN ISO 13849-1 |
None |
Contactor control function block |
No |
Supporting protocol for AS-Interface Safety at Work |
No |
Supporting protocol for DeviceNet Safety |
No |
Supporting protocol for EtherNet/IP |
No |
Supporting protocol for Foundation Fieldbus |
No |
Supporting protocol for PROFINET CBA |
No |
Supporting protocol for PROFINET IO |
No |
Supporting protocol for PROFIsafe |
No |
Supporting protocol for SafetyBUS p |
No |
Supply voltage AC 50 Hz |
0 V |
Supply voltage AC 60 Hz |
0 V |
Supply voltage DC |
18-30 V |
Suitable for temperature control |
No |
Radio standard GPRS |
No |
Radio standard GSM |
No |
Radio standard UMTS |
No |
SIL according to IEC 61508 |
None |
Degree of protection (NEMA) |
1 |