Item condition |
New |
Manufacture name |
DeviceNet analog input unit, 4 x inputs 0/4 to 20 mA, 0/1 to 5 V, 0 to DRT20069M |
Brand |
Omron
|
Categories |
Programmable logic controllers
|
Country of origin |
NL |
Harmonized System Code |
8471 6070 00
|
Width |
115 mm |
Height |
50 mm |
Depth |
49.7 mm |
Suitable for safety functions |
No |
Number of analogue inputs |
4 |
Number of analogue outputs |
0 |
Voltage type of supply voltage |
DC |
Supporting protocol for LON |
No |
Number of HW-interfaces industrial Ethernet |
0 |
Number of HW-interfaces RS-232 |
0 |
Number of HW-interfaces RS-422 |
0 |
Number of HW-interfaces RS-485 |
0 |
Number of HW-interfaces serial TTY |
0 |
Number of HW-interfaces USB |
0 |
Number of HW-interfaces parallel |
0 |
Number of HW-interfaces other |
1 |
Supporting protocol for TCP/IP |
No |
Supporting protocol for ASI |
No |
Supporting protocol for PROFIBUS |
No |
Supporting protocol for CAN |
No |
Supporting protocol for INTERBUS |
No |
Supporting protocol for KNX |
No |
Supporting protocol for Modbus |
No |
Supporting protocol for Data-Highway |
No |
Supporting protocol for DeviceNet |
Yes |
Supporting protocol for SUCONET |
No |
Supporting protocol for other bus systems |
No |
Input, current |
Yes |
Input, voltage |
No |
Input, resistor |
No |
Input, resistance thermometer |
No |
Input, thermocouple |
No |
Input signal, configurable |
Yes |
Output, current |
No |
Output, voltage |
No |
Output signal configurable |
No |
Resolution of the analogue inputs |
15 Bit |
Type of electric connection |
Screw connection |
Rail mounting possible |
Yes |
Explosion safety category for gas |
None |
Explosion safety category for dust |
None |
Fieldbus connection over separate bus coupler possible |
No |
System accessory |
No |
Appendant operation agent (Ex ia) |
No |
Appendant operation agent (Ex ib) |
No |
Degree of protection (IP) |
IP20 |
Supporting protocol for SERCOS |
No |
Supporting protocol for INTERBUS-Safety |
No |
Number of interfaces PROFINET |
0 |
Number of HW-interfaces Wireless |
0 |
Front built-in possible |
No |
Rack-assembly possible |
No |
Wall mounting/direct mounting |
No |
Radio standard Bluetooth |
No |
Radio standard Wi-Fi 802.11 |
No |
IO link master |
No |
Performance level according to EN ISO 13849-1 |
Level a |
Supporting protocol for AS-Interface Safety at Work |
No |
Supporting protocol for DeviceNet Safety |
No |
Supporting protocol for EtherNet/IP |
No |
Supporting protocol for Foundation Fieldbus |
No |
Supporting protocol for PROFINET CBA |
No |
Supporting protocol for PROFINET IO |
No |
Supporting protocol for PROFIsafe |
No |
Supporting protocol for SafetyBUS p |
No |
Supply voltage AC 50 Hz |
NA V |
Supply voltage AC 60 Hz |
NA V |
Supply voltage DC |
20.4-26.4 V |
Analogue inputs configurable |
Yes |
Analogue outputs configurable |
No |
Radio standard GPRS |
No |
Radio standard GSM |
No |
Radio standard UMTS |
No |
SIL according to IEC 61508 |
None |
Degree of protection (NEMA) |
Other |