Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Variable frequency drive, 500 V AC, 3-phase, 125 A, 75 kW, IP21/NEMA1, DC link choke image 1
Variable frequency drive, 500 V AC, 3-phase, 125 A, 75 kW, IP21/NEMA1, DC link choke image 2
Variable frequency drive, 500 V AC, 3-phase, 125 A, 75 kW, IP21/NEMA1, DC link choke image 3
Variable frequency drive, 500 V AC, 3-phase, 125 A, 75 kW, IP21/NEMA1, DC link choke image 4
Variable frequency drive, 500 V AC, 3-phase, 125 A, 75 kW, IP21/NEMA1, DC link choke thumbnail 1
Variable frequency drive, 500 V AC, 3-phase, 125 A, 75 kW, IP21/NEMA1, DC link choke thumbnail 2
Variable frequency drive, 500 V AC, 3-phase, 125 A, 75 kW, IP21/NEMA1, DC link choke thumbnail 3
Variable frequency drive, 500 V AC, 3-phase, 125 A, 75 kW, IP21/NEMA1, DC link choke thumbnail 4

Variable frequency drive, 500 V AC, 3-phase, 125 A, 75 kW, IP21/NEMA1, DC link choke

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
5 883,12 €
This price is valid until 24.12.24
EAN: 4015081772407
MPN: 9703-5012-00P
Package: 1

Technical Information

Item condition New
Manufacture name Variable frequency drive, 500 V AC, 3-phase, 125 A, 75 kW, IP21/NEMA1, DC link choke
Brand EATON
Categories Control gear
Country of origin CN
Width 288 mm
Height 888.5 mm
Depth 340.7 mm
With control element Yes
Number of digital inputs 8
Number of digital outputs 1
Number of analogue inputs 2
Number of analogue outputs 2
Supporting protocol for LON No
Number of HW-interfaces industrial Ethernet 1
Number of HW-interfaces RS-232 0
Number of HW-interfaces RS-422 0
Number of HW-interfaces RS-485 1
Number of HW-interfaces serial TTY 0
Number of HW-interfaces USB 0
Number of HW-interfaces parallel 0
Number of HW-interfaces other 1
With optical interface No
Supporting protocol for TCP/IP Yes
Supporting protocol for ASI No
Supporting protocol for PROFIBUS Yes
Supporting protocol for CAN Yes
Supporting protocol for INTERBUS No
Supporting protocol for KNX No
Supporting protocol for Modbus Yes
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet Yes
Supporting protocol for SUCONET No
Supporting protocol for other bus systems Yes
Degree of protection (IP) IP21
With PC connection Yes
Supporting protocol for SERCOS No
Supporting protocol for INTERBUS-Safety No
Mains voltage 525-600 V
Mains frequency 50/60 Hz
4-quadrant operation possible No
Number of interfaces PROFINET 0
Type of converter U converter
Number of phases output 3
Number of phases input 3
Integrated breaking resistance No
Application in industrial area permitted Yes
Application in domestic- and commercial area permitted Yes
Max. output frequency 400 Hz
Max. output at linear load at rated output voltage 90 kW
Max. output at quadratic load at rated output voltage 110 kW
Relative symmetric net voltage tolerance 10 %
Relative symmetric net frequency tolerance 10 %
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for EtherNet/IP Yes
Supporting protocol for Foundation Fieldbus No
Supporting protocol for PROFINET CBA No
Supporting protocol for PROFINET IO Yes
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Max. output voltage 600 V
Nominal output current I2N 125 A
Supporting protocol for BACnet Yes
Degree of protection (NEMA) 1

Packing details

Packing level 1 4015081772407

Description

Variable frequency drive, Part group reference (e.g. DIL): DG1, Rated operational voltage: Ue = 600 V AC, 3-phase, Output voltage with Ve: U2 = 600 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 500 (-10%) - 600 (+10%) V, Rated operational current At 150% overload: Ie = 125 A, Note: Rated operational current for a switching frequency of 1 - 6 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload, Rated operational current At 110% overload: Ie = 144 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole , three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 525 V, 50 Hz, Assigned motor rating 150 % Overload: P = 75 kW, 110 % Overload: P = 90 kW, 150 % Overload: IM = 107 A, 110 % Overload: IM = 129 A, Assigned motor rating Note: at 600 V, 50 Hz, Assigned motor rating 150 % Overload: P = 90 kW, 110 % Overload: P = 110 kW, 150 % Overload: IM = 112 A, 110 % Overload: IM = 137 A, Assigned motor rating Note: at 600 V, 60 Hz, Assigned motor rating 150 % Overload: P = 125 HP, 110 % Overload: P = 150 HP, Assigned motor rating 150 % Overload: IM = 99 A, 110 % Overload: IM = 125 A , Degree of Protection: IP21/NEMA1, Interface/field bus (built-in): Modbus RTU, Modbus TCP, BACnet MS/TP, Ethernet IP, Fieldbus connection (optional): PROFIBUS, CANopen®, DeviceNet, SmartWire-DT, Fitted with: Radio interference suppression filter, Additional PCB protection, Multi-line graphic display, DC link choke, Frame size: FS5, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5

Similar items

Similar items

Similar items
4015081721900 4015081721924 4015081721931 4015081721658 4015081721788 4015081721719 4015081721665 4015081721962 4015081721955
Similar items
4015081721689 4015081684021 4015081721658 4015081721924 4015081721955 4015081721726 4015081721702 4015081721962 4015081721719