Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 1
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 2
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 3
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 4
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 5
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 6
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 7
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 8
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 9
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 10
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 11
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 12
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 13
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 14
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 15
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 16
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 17
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated image 18
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 1
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 2
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 3
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 4
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 5
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 6
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 7
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 8
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 9
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 10
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 11
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 12
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 13
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 14
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 15
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 16
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 17
Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated thumbnail 18

Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
200,15 €
This price is valid until 24.12.24
EAN: 4015081935031
MPN: 192759
Package: 1

Technical Information

Item condition New
Manufacture name Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated
Brand EATON
Categories Modular switches
Country of origin DE
Harmonized System Code 8536 5080 00
Width 45 mm
Height 206 mm
Depth 149.5 mm
With transformer No
Rated operation power at AC-3, 400 V 1.1 kW
Number of command positions 0
Number of auxiliary contacts as normally open contact 1
Number of auxiliary contacts as normally closed contact 0
Suitable for emergency stop No
Rated operation current Ie 1.2 A
Number of indicator lights 0
Overload release current setting 0.3-1.2 A
Supporting protocol for LON No
Supporting protocol for TCP/IP No
Supporting protocol for ASI No
Supporting protocol for PROFIBUS No
Supporting protocol for CAN No
Supporting protocol for INTERBUS No
Supporting protocol for Modbus No
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet No
Supporting protocol for SUCONET No
Supporting protocol for other bus systems No
External reset possible No
Rail mounting possible Yes
Rated control supply voltage at AC 50 Hz 0 V
Rated control supply voltage at AC 60 Hz 0 V
Rated control supply voltage at DC 24 V
Degree of protection (IP) IP20
Supporting protocol for SERCOS No
Supporting protocol for INTERBUS-Safety No
Release class Adjustable
With short-circuit release Yes
With fuse No
Type of electrical connection of main circuit Screw connection
Type of electrical connection for auxiliary- and control current circuit Screw connection
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for EtherNet/IP No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for PROFINET CBA No
Supporting protocol for PROFINET IO No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Voltage type for actuating DC
Type of motor starter Direct online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase 0.18 kW
Rated power, 460 V, 60 Hz, 3-phase 0 kW
Rated power, 575 V, 60 Hz, 3-phase 0 kW
Rated operation current at AC-3, 400 V 1.2 A
Ambient temperature, upper operating limit 55 °C
Temperature compensated overload protection Yes
Rated conditional short-circuit current, type 2, 400 V 100000 A
Rated conditional short-circuit current, type 2, 230 V 100000 A
Rated conditional short-circuit current, type 1, 480 Y/277 V 0 A
Rated conditional short-circuit current, type 1, 600 Y/347 V 0 A
Degree of protection (NEMA) Other
Coordination class according to IEC 60947-4-3 Class 2

Packing details

Packing level 1 4015081935031

Description

Direct starter, 3-pole, 0.09 - 0.37 kW/400 V/AC3, 100 kA, electronic protection, standard, DC-operated