Register to unlock your exclusive B2B prices and start shopping. Sign up now!
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage image 1
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage image 2
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage image 3
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage image 4
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage image 5
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage image 6
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage image 7
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage image 8
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage image 9
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage image 10
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage image 11
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage image 12
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage image 13
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage image 14
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage image 15
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage image 16
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage image 17
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage thumbnail 1
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage thumbnail 2
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage thumbnail 3
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage thumbnail 4
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage thumbnail 5
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage thumbnail 6
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage thumbnail 7
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage thumbnail 8
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage thumbnail 9
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage thumbnail 10
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage thumbnail 11
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage thumbnail 12
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage thumbnail 13
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage thumbnail 14
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage thumbnail 15
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage thumbnail 16
DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage thumbnail 17

DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
83,50 €
This price is valid until 24.12.24
EAN: 4015081861750
MPN: 188290
Package: 1

Technical Information

Item condition New
Manufacture name DOL starter, 380 V 400 V 415 V: 7.5 kW, Ir= 10 - 16 A, 230 V 50 Hz, 240 V 60 Hz, Alternating voltage
Brand EATON
Categories Modular switches
Country of origin DE
Harmonized System Code 8536 5080 00
Width 45 mm
Height 170 mm
Depth 76 mm
With transformer No
Rated operation power at AC-3, 400 V 7.5 kW
Number of command positions 0
Number of auxiliary contacts as normally open contact 1
Number of auxiliary contacts as normally closed contact 0
Suitable for emergency stop No
Rated operation current Ie 15.2 A
Number of indicator lights 0
Overload release current setting 10-16 A
Supporting protocol for LON No
Supporting protocol for TCP/IP No
Supporting protocol for ASI No
Supporting protocol for PROFIBUS No
Supporting protocol for CAN No
Supporting protocol for INTERBUS No
Supporting protocol for Modbus No
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet No
Supporting protocol for SUCONET No
Supporting protocol for other bus systems No
External reset possible No
Rail mounting possible Yes
Rated control supply voltage at AC 50 Hz 230 V
Rated control supply voltage at AC 60 Hz 0 V
Rated control supply voltage at DC 0 V
Degree of protection (IP) IP20
Supporting protocol for SERCOS No
Supporting protocol for INTERBUS-Safety No
Release class CLASS 10 A
With short-circuit release Yes
With fuse No
Type of electrical connection of main circuit Screw connection
Type of electrical connection for auxiliary- and control current circuit Screw connection
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for EtherNet/IP No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for PROFINET CBA No
Supporting protocol for PROFINET IO No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Voltage type for actuating AC
Type of motor starter Direct online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase 4 kW
Rated power, 460 V, 60 Hz, 3-phase 0 kW
Rated power, 575 V, 60 Hz, 3-phase 0 kW
Rated operation current at AC-3, 400 V 15 A
Ambient temperature, upper operating limit 55 °C
Temperature compensated overload protection Yes
Rated conditional short-circuit current, type 2, 400 V 0 A
Rated conditional short-circuit current, type 2, 230 V 0 A
Rated conditional short-circuit current, type 1, 480 Y/277 V 0 A
Rated conditional short-circuit current, type 1, 600 Y/347 V 0 A
Degree of protection (NEMA) Other
Coordination class according to IEC 60947-4-3 Class 1

Packing details

Packing level 1 4015081861750

Description

DOL starter, Basic device: MSC, Notes: Not suitable for motors with efficiency class IE3., Motor ratings Motor rating AC-3 380 V 400 V 415 V: P= 7.5 kW, Setting range of overload releases: Ir= 10 - 16 A, Actuating voltage: 230 V 50 Hz, 240 V 60 Hz, Alternating voltage, Standards: IEC/EN 60947-4-1, VDE 0660