Item condition |
New |
Manufacture name |
DS1-X for ET 200S Standard direct on-line starter, expandable 4.5-6.3 A |
Brand |
Siemens
|
Categories |
Modular switches
|
Country of origin |
DE |
Harmonized System Code |
8536 4900 00
|
Width |
45 mm |
Height |
265 mm |
Depth |
120 mm |
With transformer |
No |
Rated operation power at AC-3, 400 V |
2.2 kW |
Number of command positions |
UN |
Number of auxiliary contacts as normally open contact |
UN |
Number of auxiliary contacts as normally closed contact |
UN |
Suitable for emergency stop |
- |
Rated operation current Ie |
UN A |
Number of indicator lights |
UN |
Overload release current setting |
4.5-6.3 A |
Supporting protocol for LON |
- |
Supporting protocol for TCP/IP |
- |
Supporting protocol for ASI |
No |
Supporting protocol for PROFIBUS |
- |
Supporting protocol for CAN |
- |
Supporting protocol for INTERBUS |
- |
Supporting protocol for Modbus |
- |
Supporting protocol for Data-Highway |
- |
Supporting protocol for DeviceNet |
- |
Supporting protocol for SUCONET |
- |
Supporting protocol for other bus systems |
- |
External reset possible |
- |
Rail mounting possible |
- |
Rated control supply voltage at AC 50 Hz |
UN V |
Rated control supply voltage at AC 60 Hz |
UN V |
Rated control supply voltage at DC |
20.4-28.8 V |
Supporting protocol for SERCOS |
- |
Supporting protocol for INTERBUS-Safety |
- |
With short-circuit release |
Yes |
With fuse |
- |
Type of electrical connection of main circuit |
Screw connection |
Supporting protocol for AS-Interface Safety at Work |
- |
Supporting protocol for DeviceNet Safety |
- |
Supporting protocol for EtherNet/IP |
- |
Supporting protocol for Foundation Fieldbus |
- |
Supporting protocol for PROFINET CBA |
- |
Supporting protocol for PROFINET IO |
- |
Supporting protocol for PROFIsafe |
- |
Supporting protocol for SafetyBUS p |
- |
Voltage type for actuating |
DC |
Rated operation power at AC-3, 230 V, 3-phase |
UN kW |
Rated power, 460 V, 60 Hz, 3-phase |
UN kW |
Rated power, 575 V, 60 Hz, 3-phase |
UN kW |
Rated operation current at AC-3, 400 V |
6.3 A |
Ambient temperature, upper operating limit |
UN °C |
Temperature compensated overload protection |
- |
Rated conditional short-circuit current, type 2, 400 V |
UN A |
Rated conditional short-circuit current, type 2, 230 V |
UN A |
Rated conditional short-circuit current, type 1, 480 Y/277 V |
UN A |
Rated conditional short-circuit current, type 1, 600 Y/347 V |
UN A |
Coordination class according to IEC 60947-4-3 |
Class 1 |