Register to unlock your exclusive B2B prices. Register now
RS485 bus wireless three-phase energy meter, MID approval image 1

RS485 bus wireless three-phase energy meter, MID approval

In stock price (excl. VAT):
164,21 €
This price is valid until 2024-12-31
Price per m: 164,21 €
EAN: 4010312501733
MPN: 28365715
Our warehouse: No Vendor stock: No
Per package: 1 Per box: 1 Per pallet: N/A
Technical data
Item condition New
Brand ELTAKO
Categories Electric meters
Country of origin CN
Harmonized System Code 9028 3019 00
Mounting method DRA (DIN-rail adapter)
Width 70 mm
Height 82 mm
Depth 58 mm
Frequency 50 Hz
Max. current (Imax) 80 A
Width in number of modular spacings 4
Degree of protection (IP) IP20
Pole type Four conductor
Nominal voltage (Un) N-L 230 V
Nominal current (In) 10 A
Packing details
Packing level 1 4010312501733, 4010312501733
Packing level 2 4010312501733
Downloads
Other Technical data
Model Direct measurement
Suitable for Purchase
Type of indication Digital
Number of positions total (counter) 7
Type of meter Electronic
Type of interface RS-485
Energy type Effective power
Tariff type Two-tariff
Tariff control External
Escapement mechanism Yes
Calibrated Yes
Approval Measuring Instruments Directive
Pulse output Electrical
Accuracy class B
Measurement type load profile -
EEC40 signature -
With lock code -
Nominal voltage (Un) L-L 400 V
Description
RS485 bus wireless three-phase energy meter. Maximum current 3x80A. Standby loss 0.8W at L1 and only 0.5W at L2 and L3 each. Modulair device for DIN-EN 60715 TH35 rail mounting in distribution cabinets with IP51 protection class. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With RS485 interface. It measures active energy by means of the current between input and output. The internal power consumption of 0.8W or 0.5W active power per path is neither metered nor indicated. 1, 2 or 3 phase conductors with max. currents up to 80A can be connected. The inrush current is 40mA. The terminals ‹L1 and N must always be connected. Connection to the Eltako RS485 bus via a FBA14 by means of a 2-wire screened bus line (e.g. telephone line). The meter reading and the momentary capacity are transferred to the bus – e.g. for transfer to an external computer or a Professional Smart Home controller – and is also transferred to the wireless network via the FAM14. For this it is necessary that a device address is assigned from the wireless antenna module FAM14, according to the operating instructions. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. The power consumption is displayed with a LED flashing 1000 times per kWh next to the display. Designed as standard for using as double-tariff meter: Switch over to a second tariff by applying 230 V to terminals E1/E2. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu according to the operation manual. First the background lighting switches on. The display then shows the total active energy per tariff, the active energy per resettable memory RS1 or RS2, and the instantaneous values of consumption, voltage and current per phase. Error message (false): When the phase conductor is missing or the current direction is wrong false and the corresponding phase conductor are indicated on the display.