Register to unlock your exclusive B2B prices and start shopping. Sign up now!
M-bus three-phase energy meter, MID approval image 1

M-bus three-phase energy meter, MID approval

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
199,59 €
This price is valid until 31.12.24
EAN: 4010312501726
MPN: 28380512
Package: 1

Technical Information

Item condition New
Manufacture name M-bus three-phase energy meter, MID approval
Brand ELTAKO
Categories Electric meters
Country of origin CN
Harmonized System Code 9028 3019 00
Mounting method DRA (DIN-rail adapter)
Width 70 mm
Height 82 mm
Depth 58 mm
Frequency 50 Hz
Max. current (Imax) 80 A
Width in number of modular spacings 4
Degree of protection (IP) IP20
Pole type Four conductor
Nominal voltage (Un) N-L 230 V
Nominal current (In) 10 A

Packing details

Packing level 1 4010312501726, 4010312501726
Packing level 2 4010312501726

Other Technical data

Model Direct measurement
Suitable for Purchase
Type of indication Digital
Number of positions total (counter) 7
Type of meter Electronic
Type of interface M-bus (wired)
Energy type Effective power
Tariff type Two-tariff
Tariff control External
Escapement mechanism Yes
Calibrated Yes
Approval Measuring Instruments Directive
Accuracy class B
Measurement type load profile -
EEC40 signature -
With lock code -
Nominal voltage (Un) L-L 400 V

Downloads

Description

M-bus three-phase energy meter. Maximum current 3x80A. Standby loss 0.5 watt per path only. Modular device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With M-bus interface. It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. 1, 2 or 3 phase conductors with max. currents up to 80A can be connected. The inrush current is 4OmA. The N terminal must always be connected. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. Power consumption is indicated by an LED flashing at a rate of 1000 times per KWh. Designed as standard for using as double-tariff meter: Switch over to a second tariff by applying 230V to terminals E1/E2. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu. First the background lighting switches on. The display then shows the total active energy per tariff, the active energy of the resettable memory RS1 or RS2 as well as the instantaneous values of ­consumption, voltage and current per phase. Error message (false): When the phase conductor is missing or the current direction is wrong false and the corresponding phase conductor are indicated on the display. M-bus data transfer: On read-out all values are transferred in a telegram. The following telegrams are supported: - Initialisation: SND_NKE, Reply: ACK. - Read out meter: REQ_UD2, Reply: RSP_UD. - Change primary address: SND_UD, Reply: ACK. - Reset RS1: SND_UD, Reply: ACK. - Slave selection for the secondary address Reply: ACK. The device does not reply to unknown requests: The transfer rate is detected automatically. The device has a voltage monitor. In case of voltage loss, all registers are saved in the EEPROM. Changing the M-bus primary address: To change the M-bus primary address, hold down SELECT for 3s. In the menu that appears, press MODE to increment the address by 10. Press SELECT to increment by 1. When the required primary address is set, wait until the main menu reappears. Secondary address: It is possible to communicate with the energy meters according to the standard EN13757 using the secondary address. The use of wild cards is possible. For details refer to the operating instructions at www.eltako.com.