Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 1
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 2
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 3
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 4
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 5
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 6
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 7
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 8
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 9
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A thumbnail 1
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A thumbnail 2
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A thumbnail 3
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A thumbnail 4
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A thumbnail 5
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A thumbnail 6
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A thumbnail 7
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A thumbnail 8
Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A thumbnail 9

Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
99,72 €
This price is valid until 24.12.24
EAN: 4015081648726
MPN: 168295
Package: 1
Box: 60

Technical Information

Item condition New
Manufacture name Electronic RCD/MCB combination, 13 A, 10 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A
Brand EATON
Categories Leakage protection
Country of origin CZ
Harmonized System Code 8536 2010 00
Voltage type AC
Built-in depth 70 mm
Rated current 13 A
Rated voltage 240 V
Release characteristic B
Rated insulation voltage Ui 250 V
Rated fault current 0.01 A
Leakage current type A
Surge current capacity 3 kA
Current limiting class 3
Over voltage category 3
Pollution degree 2
Width in number of modular spacings 2
Frequency 50 Hz
Degree of protection (IP) IP20
Number of protected poles 2
Concurrently switching neutral conductor No
Rated short-circuit breaking capacity according to IEC 60947-2 0 kA
Connectable conductor cross section solid-core 1-25 mm²
Connectable conductor cross section multi-wired 1-25 mm²
With interlocking device No
Ambient temperature during operating -25-40 °C
Flush-mounted installation No
Number of poles (total) 2
Anti-nuisance tripping version Yes
Rated impulse withstand voltage Uimp 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1 10 kA
Disconnection characteristic Short-time delayed
Rated short-circuit breaking capacity according to EN 61009 10 kA

Packing details

Packing level 1 4015081648726
Packing level 2 9008790489037

Description

High-quality residual current device/miniature circuit breaker combination, line voltage-dependent, contact position indicator red - green, terminal rear plug protection, tri-stable slide catch - enables removal from existing busbar system, comprehensive range of accessories suitable for subsequent installation, wide range of rated fault currents, rated operational currents up to 40 A, tripping characteristics B, C, D, rated breaking capacity 10 kA, suitable for outdoor use (on-site power and outdoor distribution board) up to -25 °C