Technical Information
Item condition |
New |
Manufacture name |
Impulse switch, 1 NO contact 10A |
Brand |
ELTAKO
|
Categories |
Relays
|
Country of origin |
CN |
Harmonized System Code |
8536 5080 00
|
Mounting method |
Other |
Function |
Other |
Built-in depth |
18 mm |
Width in number of modular spacings |
3.1 |
Control voltage 1 |
8-230 V |
Control voltage 2 |
230 V |
Type of control voltage 1 |
AC/DC |
Type of control voltage 2 |
AC |
Suitable for manual operation |
No |
Voltage type of supply voltage |
AC |
Supply voltage |
250 V |
Max. switching current (cos phi = 0.6) |
4 A |
Max. incandescent lamp load |
2000 W |
Max. load fluorescent lamp |
1000 VA |
Max. load fluorescent lamp (Duo circuit) |
1000 VA |
Max. load fluorescent lamp (parallel compensated) |
500 VA |
Rated switch current |
10 A |
Number of contacts as normally closed contact |
0 |
Number of contacts as normally open contact |
1 |
Number of contacts as change-over contact |
0 |
Packing details
Packing level 1 |
4010312107966, 4010312107966 |
Packing level 2 |
4010312107966 |
Packing level 3 |
4010312107966 |
Downloads
Description
1 NO contact potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamp load up to 2000W. No standby loss. For installation. 45mm long, 45mm wide, 18mm deep. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. Either universal control voltage 8 to 230V UC at the control input +A1/-A2 or 230V with a glow lamp current up to 5mA at the control input (L)/-A2(N). Using two potentials simultaneously at the control inputs is not permitted. Very low switching noise. No permanent power supply necessary, therefore no standby loss. By using a bistable relay coil power loss and heating is avoided even in the on mode. The relay contact can be open or closed when putting into operation. It will be synchronised at first operation. If this impulse switch is in a circuit, which is monitored by a FR12-230V mains disconnection relay, no additional base load is required. However, the monitoring voltage of the FR12-230V must be set to max. The electronics does not have an internal power supply and therefore no power is consumed in any contact position. A control current flows only during a short control impulse of 0.2 seconds. This activates the microcontroller, reads the last switching state from the non-voltage memory, switches the bistable relay to its opposite state accordingly and rewrites the new switching state to memory.