Technical data
Item condition New
Brand Schneider Electric
Categories Relays
Country of origin BE
Mounting method DIN rail
Function Mechanical
Built-in depth 84.000 mm
Rated current 16.000 A
Width in number of modular spacings 1.000
Control voltage 1 230.000-240.000 V
Control voltage 2 110.000 V
Type of control voltage 1 AC
Type of control voltage 2 DC
Frequency control voltage 1 50.000-60.000 Hz
Voltage type of supply voltage AC
Supply voltage 24.000-250.000 V
Max. switching current (cos phi = 0.6) 16.000 A
Max. incandescent lamp load 1600.000 W
Max. load fluorescent lamp 1300.000 VA
Max. load fluorescent lamp (Duo circuit) 2000.000 VA
Max. load fluorescent lamp (parallel compensated) 900.000 VA
Number of contacts as normally closed contact 0.000
Number of contacts as normally open contact 1.000
Number of contacts as change-over contact 1.000
Packing details
Packing level 1 3606480091926
Packing level 2 3606480091923
Packing level 3 3606480091924
Downloads
Description
This Acti9 iETL iTL 16 is a modular extension for impulse relay. This 2P device has 1 changeover and 1 normally open contact. Rated current is 16A, 24VAC to 250VAC operating voltage and it operates with 230VAC to 240VAC or 110VDC control voltage. Electrical endurance goes up to 200000 cycles for AC-21 or 100000 cycles for AC-22. The switching frequency is 5 switching operations/minute or 100 switching operations/day. The duration of the command order should be 50ms. It is mainly used for lighting control applications. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Pollution degree is 3. Overvoltage category is IV. The degree of protection is IP20 and IP40 in an enclosure. The operating temperature is from -20°C to 50°C. The storage temperature is from -40°C to 70°C . This product is compliant with IEC/EN 60669-1 and IEC/EN 60669-2-2 standard.