Register to unlock your exclusive B2B prices. Register now
fan coil act. KNX DRA image 1

fan coil act. KNX DRA

In stock price (excl. VAT):
256,91 €
This price is valid until 2024-12-31
Price per m: 256,91 €
EAN: 4010337059387
MPN: 216300
Our warehouse: No Vendor stock: No
Per package: 1 Per box: N/A
Technical data
Item condition New
Manufacture name fan coil act. KNX DRA
Brand Gira
Categories Sensors
Country of origin DE
Harmonized System Code 8536 4900 00
Mounting method DRA (DIN-rail adapter)
Rated current 0 A
Output power 0 W
Rated operating voltage NA V
Bus system KNX Yes
Bus system radio frequent No
Bus system Powernet No
Max. switching power 0 W
With bus connection No
Max. number of switching contacts 4
Number of digital inputs NA
Width in number of modular spacings 4
Max. switching current 0 A
Other bus systems None
Bus system LON No
Suitable for C-load No
Different phases connectable -
Local operation/hand operation No
Degree of protection (IP) IP20
With LED indication No
Modular expandability -
Bus system KNX radio No
Radio frequent bidirectional -
Bus module detachable -
Min. depth of built-in installation box 0 mm
Max. switching power LED NA W
Packing details
Packing level 1 4010337059387
Description
Fan coil actuator for KNX DRA plus Features: Fan coil actuator for operation of ventilator convectors (fan coil units), implemented for room air conditioning. The actuator receives telegrams, for example from room temperature controllers, and converts corrected variable telegrams into equivalent fan speeds and valve positions. Connection of a ventilator convector with up to six ventilator gradations or connection of two ventilator convectors each with up to three fan speeds with double pipe systems. Manual actuation. Building site operation: Outputs can be operated manually without bus voltage with operating voltage only. Operating modes for heating or cooling mode, or combined heating cooling mode. Double tube or quadruple tube operation. Double tube system heats or cools via a shared water cycle. Quadruple tube system consists of separate flow and return for heating and cooling. Individual or hierarchic switching of fan speeds. Feedback, output indication, block function for each channel, level limitation. Behaviour after bus voltage failure or bus mains voltage failure and following an ETS programming process can be configured. Limit values can be set. Cyclical or event-oriented transmission. Free channels can be used for switching functions, e.g. for room lighting Notes : VDE approval in accordance with EN 60669-1, EN 60669-2-1. Installation on DIN top-hat rail.