Register to unlock your exclusive B2B prices and start shopping. Sign up now!
FS401E-C32/0.03 Residual Current Circuit Breaker with Overcurrent Protection image 1
FS401E-C32/0.03 Residual Current Circuit Breaker with Overcurrent Protection image 2
FS401E-C32/0.03 Residual Current Circuit Breaker with Overcurrent Protection image 3
FS401E-C32/0.03 Residual Current Circuit Breaker with Overcurrent Protection image 4
FS401E-C32/0.03 Residual Current Circuit Breaker with Overcurrent Protection image 5
FS401E-C32/0.03 Residual Current Circuit Breaker with Overcurrent Protection thumbnail 1
FS401E-C32/0.03 Residual Current Circuit Breaker with Overcurrent Protection thumbnail 2
FS401E-C32/0.03 Residual Current Circuit Breaker with Overcurrent Protection thumbnail 3
FS401E-C32/0.03 Residual Current Circuit Breaker with Overcurrent Protection thumbnail 4
FS401E-C32/0.03 Residual Current Circuit Breaker with Overcurrent Protection thumbnail 5

FS401E-C32/0.03 Residual Current Circuit Breaker with Overcurrent Protection

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
92,53 € per pcs
This price is valid until 01.01.25
EAN: 7612270104598
MPN: 2CCL562110E0324
Package: 1
Box: 2

Technical Information

Item condition New
Manufacture name FS401E-C32/0.03 Residual Current Circuit Breaker with Overcurrent Protection
Brand ABB
Categories Leakage protection
Voltage type AC
Built-in depth 91 mm
Rated current 32 A
Rated voltage 230 V
Release characteristic C
Rated insulation voltage Ui 500 V
Rated fault current 0.03 A
Leakage current type A
Surge current capacity 0.25 kA
Current limiting class 3
Over voltage category 3
Pollution degree 2
Width in number of modular spacings 1
Frequency 50/60 Hz
Degree of protection (IP) IP20
Number of protected poles 1
Concurrently switching neutral conductor No
Rated short-circuit breaking capacity according to IEC 60947-2 10 kA
Connectable conductor cross section solid-core 0.75-35 mm²
Connectable conductor cross section multi-wired 0.75-35 mm²
With interlocking device Yes
Ambient temperature during operating -25-40 °C
Flush-mounted installation No
Number of poles (total) 2
Anti-nuisance tripping version No
Rated impulse withstand voltage Uimp 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1 6 kA
Disconnection characteristic Undelayed
Rated short-circuit breaking capacity according to EN 61009 6 kA

Packing details

Packing level 1 7612270104598
Packing level 2 7612270104598, 7612270104598

Downloads

Description

FS401E-C25/0,03