Register to unlock your exclusive B2B prices and start shopping. Sign up now!
FS403MK-B25/0.03 Residual Current Circuit Breaker with Overcurrent Protection image 1
FS403MK-B25/0.03 Residual Current Circuit Breaker with Overcurrent Protection image 2
FS403MK-B25/0.03 Residual Current Circuit Breaker with Overcurrent Protection thumbnail 1
FS403MK-B25/0.03 Residual Current Circuit Breaker with Overcurrent Protection thumbnail 2

FS403MK-B25/0.03 Residual Current Circuit Breaker with Overcurrent Protection

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
196,16 € per pcs
This price is valid until 01.01.25
EAN: 7612271470814
MPN: 2CCL563310E0255
Box: 1

Technical Information

Item condition New
Manufacture name FS403MK-B25/0.03 Residual Current Circuit Breaker with Overcurrent Protection
Brand ABB
Categories Leakage protection
Harmonized System Code 8536 2010 00
Voltage type AC
Built-in depth 72 mm
Rated current 25 A
Rated voltage 415 V
Release characteristic B
Rated insulation voltage Ui 500 V
Rated fault current 0.03 A
Leakage current type A
Current limiting class 3
Over voltage category 3
Pollution degree 2
Width in number of modular spacings 4
Frequency 50/60 Hz
Degree of protection (IP) IP2X
Number of protected poles 3
Concurrently switching neutral conductor No
Rated short-circuit breaking capacity according to IEC 60947-2 10 kA
Connectable conductor cross section solid-core 0.75-35 mm²
Connectable conductor cross section multi-wired 0.75-35 mm²
With interlocking device Yes
Ambient temperature during operating -25-40 °C
Flush-mounted installation No
Number of poles (total) 4
Anti-nuisance tripping version Yes
Rated impulse withstand voltage Uimp 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1 10 kA
Disconnection characteristic Short-time delayed
Rated short-circuit breaking capacity according to EN 61009 10 kA

Packing details

Packing level 1 7612271470814

Downloads

Description

FI/LS-Schalter (RCBOs) bieten Personen- und Sachschutz sowie einen Schutz vor elektrisch gezündeten Bränden gemäß DIN VDE 0100-410 und DIN VDE 0100-530. Sie gewährleisten Schutz von Einphasenstromkreisen gegen Überlast und Kurzschlussströme, Schutz bei sinusförmigen Wechselströmen und pulsierenden Strömen mit glattem Gleichfehlerstrom von bis zu 10 mA gegen Erde. Sowie Fehlerschutz (Schutz bei indirektem Berühren), zusätzlichen Schutz (mit IΔn ≤ 30 mA) und Brandschutz (mit I∆n ≤ 300 mA). Sie haben eine höhere Unempfindlichkeit gegen ungewolltes Auslösen durch eine Kurzzeitverzögerung und können Mischfrequenzströme bis 1kHz erkennen. Sie erfüllen die Produktnorm IEC/EN 61009-1 (VDE 0664-20). Die Kontaktierung erfolgt direkt über das Stecksockelsystem Smissline TP und die Aussenleiterkontaktierung kann bei einphasigen Geräten frei gewählt werden (L1, L2 oder L3)