Item condition |
New |
Manufacture name |
Heater Burnout Detection Unit, 4 CT inputs, 4 PNP Outputs, screwless p NX020123R |
Brand |
Omron
|
Categories |
Programmable logic controllers
|
Country of origin |
NL |
Harmonized System Code |
8471 6070 00
|
Width |
12 mm |
Height |
100 mm |
Depth |
80 mm |
Input current at signal 1 |
125 mA |
Suitable for safety functions |
No |
Number of digital inputs |
0 |
Number of digital outputs |
4 |
Number of analogue inputs |
4 |
Number of analogue outputs |
0 |
Time delay at signal exchange |
10 ms |
Voltage type of supply voltage |
DC |
Supporting protocol for LON |
No |
Number of HW-interfaces industrial Ethernet |
0 |
Number of HW-interfaces RS-232 |
0 |
Number of HW-interfaces RS-422 |
0 |
Number of HW-interfaces RS-485 |
0 |
Number of HW-interfaces serial TTY |
0 |
Number of HW-interfaces USB |
0 |
Number of HW-interfaces parallel |
0 |
Number of HW-interfaces other |
1 |
With optical interface |
No |
Type of voltage (input voltage) |
DC |
Supporting protocol for TCP/IP |
No |
Supporting protocol for ASI |
No |
Supporting protocol for PROFIBUS |
No |
Supporting protocol for CAN |
No |
Supporting protocol for INTERBUS |
No |
Supporting protocol for KNX |
No |
Supporting protocol for Modbus |
No |
Supporting protocol for Data-Highway |
No |
Supporting protocol for DeviceNet |
No |
Supporting protocol for SUCONET |
No |
Supporting protocol for other bus systems |
Yes |
Output voltage at digital output |
12-24 V |
Output current at digital output |
0.1 A |
Analogue input, current |
Yes |
Analogue input, voltage |
No |
Analogue input, resistor |
No |
Analogue input, resistor temperature |
No |
Analogue input, thermocouple |
No |
Analogue input signal configurable |
No |
Analogue output, current |
No |
Analogue output, voltage |
No |
Analogue output signal configurable |
No |
Short-circuit protection, digital outputs available |
No |
Resolution of the analogue inputs |
10 Bit |
Resolution of the analogue outputs |
0 Bit |
Type of digital output |
Transistor |
Type of electric connection |
Spring clamp connection |
Rail mounting possible |
Yes |
Explosion safety category for gas |
None |
Explosion safety category for dust |
None |
Fieldbus connection over separate bus coupler possible |
Yes |
System accessory |
Yes |
Appendant operation agent (Ex ia) |
No |
Appendant operation agent (Ex ib) |
No |
Degree of protection (IP) |
IP20 |
Supporting protocol for SERCOS |
No |
Supporting protocol for INTERBUS-Safety |
No |
Number of interfaces PROFINET |
0 |
Number of HW-interfaces Wireless |
0 |
Front built-in possible |
No |
Rack-assembly possible |
No |
Wall mounting/direct mounting |
No |
Radio standard Bluetooth |
No |
Radio standard Wi-Fi 802.11 |
No |
IO link master |
No |
Performance level according to EN ISO 13849-1 |
Level a |
Supporting protocol for AS-Interface Safety at Work |
No |
Supporting protocol for DeviceNet Safety |
No |
Supporting protocol for EtherNet/IP |
No |
Supporting protocol for Foundation Fieldbus |
No |
Supporting protocol for PROFINET CBA |
No |
Supporting protocol for PROFINET IO |
No |
Supporting protocol for PROFIsafe |
No |
Supporting protocol for SafetyBUS p |
No |
Supply voltage AC 50 Hz |
NA V |
Supply voltage AC 60 Hz |
NA V |
Supply voltage DC |
20.4-28.8 V |
Type of output voltage |
DC |
Digital inputs configurable |
No |
Analogue inputs configurable |
Yes |
Analogue outputs configurable |
No |
Digital outputs configurable |
Yes |
Radio standard GPRS |
No |
Radio standard GSM |
No |
Radio standard UMTS |
No |
SIL according to IEC 61508 |
None |