Register to unlock your exclusive B2B prices and start shopping. Sign up now!
RCD/MCB combination, 40 A, 30 mA, MCB trip characteristic: B, 1p+N, RCD trip characteristic: A image 1
RCD/MCB combination, 40 A, 30 mA, MCB trip characteristic: B, 1p+N, RCD trip characteristic: A image 2
RCD/MCB combination, 40 A, 30 mA, MCB trip characteristic: B, 1p+N, RCD trip characteristic: A image 3
RCD/MCB combination, 40 A, 30 mA, MCB trip characteristic: B, 1p+N, RCD trip characteristic: A image 4
RCD/MCB combination, 40 A, 30 mA, MCB trip characteristic: B, 1p+N, RCD trip characteristic: A thumbnail 1
RCD/MCB combination, 40 A, 30 mA, MCB trip characteristic: B, 1p+N, RCD trip characteristic: A thumbnail 2
RCD/MCB combination, 40 A, 30 mA, MCB trip characteristic: B, 1p+N, RCD trip characteristic: A thumbnail 3
RCD/MCB combination, 40 A, 30 mA, MCB trip characteristic: B, 1p+N, RCD trip characteristic: A thumbnail 4

RCD/MCB combination, 40 A, 30 mA, MCB trip characteristic: B, 1p+N, RCD trip characteristic: A

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
66,85 €
This price is valid until 24.12.24
EAN: 9010238987371
MPN: 303361
Package: 1
Box: 60

Technical Information

Item condition New
Manufacture name RCD/MCB combination, 40 A, 30 mA, MCB trip characteristic: B, 1p+N, RCD trip characteristic: A
Brand EATON
Categories Leakage protection
Country of origin RO
Harmonized System Code 8536 3030 00
Voltage type AC
Built-in depth 69.5 mm
Rated current 40 A
Rated voltage 230 V
Release characteristic B
Rated insulation voltage Ui 500 V
Rated fault current 0.03 A
Leakage current type A
Surge current capacity 0.25 kA
Current limiting class 3
Over voltage category 3
Pollution degree 2
Width in number of modular spacings 2
Frequency 50 Hz
Degree of protection (IP) IP20
Number of protected poles 1
Concurrently switching neutral conductor No
Rated short-circuit breaking capacity according to IEC 60947-2 0 kA
Connectable conductor cross section solid-core 1-25 mm²
Connectable conductor cross section multi-wired 1-25 mm²
With interlocking device No
Ambient temperature during operating -25-40 °C
Flush-mounted installation No
Number of poles (total) 2
Anti-nuisance tripping version No
Rated impulse withstand voltage Uimp 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1 6 kA
Disconnection characteristic Undelayed
Rated short-circuit breaking capacity according to EN 61009 6 kA

Packing details

Packing level 1 9010238987371
Packing level 2 9010238186248

Description

RCD/MCB combination, 40 A, 30 mA, MCB trip characteristic: B, 1p+N, RCD trip characteristic: A