Register to unlock your exclusive B2B prices. Register now
IID AARDLEKSCHAKELAAR 2P 40A 300MA A image 1

IID AARDLEKSCHAKELAAR 2P 40A 300MA A

In stock price (excl. VAT):
78,38 €
This price is valid until 2024-12-24
Price per m: 78,38 €
EAN: 3606480091520
MPN: A9R04240
Our warehouse: No Vendor stock: No
Per package: 1 Per box: N/A
Technical data
Item condition New
Manufacture name IID AARDLEKSCHAKELAAR 2P 40A 300MA A
Brand Schneider Electric
Categories Leakage protection
Country of origin ES
Harmonized System Code 8536 3030 00
Mounting method DIN rail
Built-in depth 44.000 mm
Rated current 40.000 A
Rated voltage 230.000 V
Rated insulation voltage Ui 500.000 V
Number of poles 2.000
Rated fault current 300.000 A
Leakage current type A
Selective protection No
Short-circuit breaking capacity (Icw) 1.500 kA
Surge current capacity 0.250 kA
Pollution degree 3.000
Width in number of modular spacings 2.000
Short-time delayed tripping No
Frequency 50/60 Hz
Degree of protection (IP) IP20
Connectable conductor cross section solid-core 1.000-35.000 mm²
Connectable conductor cross section multi-wired 1.000-25.000 mm²
With interlocking device Yes
Ambient temperature during operating -25.000-60.000 °C
Additional equipment possible Yes
Rated impulse withstand voltage Uimp 6.000 kV
Packing details
Packing level 1 3606480091520
Description
This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 2P circuit breaker with 40A In rated current, a sensitivity of 300mA with a A type protection class. This product protects against electrical shock by indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance This product is compliant with EN/IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. The mechanical endurance is going up to 20000 cycles and electrical endurance going up to 15000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 91mm x (D) 73.5mm. The weight is 0.21kg. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 85°C.