Register to unlock your exclusive B2B prices and start shopping. Sign up now!
MD01 image 1
impulse relay iTL - 2P - 2 NO - 16A - coil 110 VDC - 230...240 VAC 50/60Hz image 2
impulse relay iTL - 2P - 2 NO - 16A - coil 110 VDC - 230...240 VAC 50/60Hz image 3
impulse relay iTL - 2P - 2 NO - 16A - coil 110 VDC - 230...240 VAC 50/60Hz image 4
MD01 thumbnail 1
impulse relay iTL - 2P - 2 NO - 16A - coil 110 VDC - 230...240 VAC 50/60Hz thumbnail 2
impulse relay iTL - 2P - 2 NO - 16A - coil 110 VDC - 230...240 VAC 50/60Hz thumbnail 3
impulse relay iTL - 2P - 2 NO - 16A - coil 110 VDC - 230...240 VAC 50/60Hz thumbnail 4

impulse relay iTL - 2P - 2 NO - 16A - coil 110 VDC - 230...240 VAC 50/60Hz

In stock: No Vendor stock: Yes Minimal order quantity: 1
Price (excl. VAT):
16,55 €
This price is valid until 31.12.24
EAN: 3606480088995
MPN: A9C30812
Package: 1
Box: 12

Technical Information

Item condition New
Manufacture name impulse relay iTL - 2P - 2 NO - 16A - coil 110 VDC - 230...240 VAC 50/60Hz
Brand Schneider Electric
Categories Relays
Country of origin BE
Harmonized System Code 8536 4900 99
Mounting method DIN rail
Function Mechanical switch
Built-in depth 43.5 mm
Width in number of modular spacings 1
Control voltage 1 230-240 V
Control voltage 2 110 V
Type of control voltage 1 AC
Type of control voltage 2 DC
Frequency control voltage 1 50-60 Hz
Suitable for manual operation Yes
Voltage type of supply voltage AC
Supply voltage 24-250 V
Max. switching current (cos phi = 0.6) 16 A
Max. incandescent lamp load 1600 W
Max. load fluorescent lamp 1300 VA
Max. load fluorescent lamp (Duo circuit) 2000 VA
Max. load fluorescent lamp (parallel compensated) 900 VA
Rated switch current 16 A
Number of contacts as normally closed contact 0
Number of contacts as normally open contact 2
Number of contacts as change-over contact 0

Packing details

Packing level 1 3606480088995
Packing level 2 3606480088992
Packing level 3 3606480088993

Downloads

Description

This Acti9 iTL is a modular impulse relay. This 2P device has 2 normally open contacts. Rated current is 16A, 24VAC to 250VAC operating voltage and it operates with 230VAC to 240VAC or 110VDC control voltage. Electrical endurance goes up to 200000 cycles for AC-21 or 100000 cycles for AC-22. The switching frequency is 5 switching operations/minute or 100 switching operations/day. The duration of the command order should be between 50ms to 1s. It is mainly used for lighting control applications. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Pollution degree is 3. Overvoltage category is IV. The dimensions are (W) 18mm x (H) 84mm x (D) 60mm. The degree of protection is IP20 and IP40 in an enclosure. The operating temperature is from -20°C to 50°C. The storage temperature is from -40°C to 70°C. This product is compliant with IEC/EN 60669-1 and IEC/EN 60669-2-2 standard.