Technical Information

Item condition New
Manufacture name ***IPRD 65R 65 KA 350V 2P TH REMOTE TRANS
Brand Schneider Electric
Categories Lighting protection
Country of origin CN
Harmonized System Code 8536 3030 99
Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact Yes
Number of conductors (without earthing) 2
Construction size 2 modular spacing
Voltage protection level 1.5 kV
Max. continuous voltage AC 350 V
Nominal discharge surge current (8/20) 20 kA
Nominal voltage AC 350 V
Nominal voltage DC 0 V
Category type 2 Yes
Voltage protection level L-N 1.5 kV
Signalling at the device Optic
Max. continuous voltage DC 0 V
Degree of protection (IP) IP20
Max. PV-voltage 0 V
Voltage protection level N-PE 1.5 kV
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 25 mm²
Max. conductor cross section flexible (fine-strand) 16 mm²
System configuration DC No
System configuration IT No
System configuration TN No
System configuration TN-C Yes
System configuration TN-S No
System configuration TT No
System configuration other No
System configuration TN-C-S No
Max. discharge surge current (8/20) 65 kA
Short-circuit breaking capacity (Isccr) 50 kA
Max. overcurrent protection device, parallel connection (fuse) 0 A
Max. overcurrent protection device, series connection (fuse) 0 A
Integrated short-circuit protection No
Integrated short-circuit protection selective to fuse gG 0 A
Leakage-current free No

Packing details

Packing level 1 3606480504860
Packing level 2 3606480504867
Packing level 3 3606480504868

Downloads

Description

This Acti9 iPRD surge arrester protects 2P installations. It allows quick replacement of damaged cartridges. This Type 2 device is recommended for very high risk level and incoming panel board. The surge arresters with r indication have remote transfer of the information Cartridge to be replaced. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The associated circuit breaker Isc breaking capacity can go up to 50kA. This Acti 9 iPRD65r is compatible with TT and TN-S earthing system. The Uc maximum continuous operating voltage in DM common mode (between phase and earth) is 350VAC. The Uc maximum continuous operating voltage in DM common mode (between phase and neutral) is 350VAC. The Up Voltage protection level in CM common mode (between phase and earth) is 1.5kV. The Up Voltage protection level in CM common mode (between phase and neutral) is 1.5kV. The Ue rated operational voltage is 230VAC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 36mm x (H) 85mm x (D) 69mm. The weight is 0.268kg. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standard.