Register to unlock your exclusive B2B prices and start shopping. Sign up now!
MD01 image 1
iPRD-DC 40r 1000PV modular surge arrester - 2P - 1000VDC - with remote transfert image 2
iPRD-DC 40r 1000PV modular surge arrester - 2P - 1000VDC - with remote transfert image 3
iPRD-DC 40r 1000PV modular surge arrester - 2P - 1000VDC - with remote transfert image 4
MD01 thumbnail 1
iPRD-DC 40r 1000PV modular surge arrester - 2P - 1000VDC - with remote transfert thumbnail 2
iPRD-DC 40r 1000PV modular surge arrester - 2P - 1000VDC - with remote transfert thumbnail 3
iPRD-DC 40r 1000PV modular surge arrester - 2P - 1000VDC - with remote transfert thumbnail 4

iPRD-DC 40r 1000PV modular surge arrester - 2P - 1000VDC - with remote transfert

In stock: Yes Vendor stock: Yes Minimal order quantity: 1
Price (excl. VAT):
59,57 €
This price is valid until 31.01.25 or while stock lasts
EAN: 3606480506673
MPN: A9L40281
Package: 1
Box: 4

Technical Information

Item condition New
Manufacture name iPRD-DC 40r 1000PV modular surge arrester - 2P - 1000VDC - with remote transfert
Brand Schneider Electric
Categories Lighting protection
Country of origin
Harmonized System Code 8536 3030 00
Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact Yes
Number of conductors (without earthing) 2
Construction size 3 modular spacing
Voltage protection level 3.9 kV
Max. continuous voltage AC 0 V
Nominal discharge surge current (8/20) 15 kA
Nominal voltage AC 0 V
Nominal voltage DC 1000 V
Category type 2 Yes
Voltage protection level L-N 3.9 kV
Signalling at the device Optic
Max. continuous voltage DC 1000 V
Degree of protection (IP) IP20
Max. PV-voltage 1000 V
Voltage protection level N-PE 3.9 kV
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 35 mm²
Max. conductor cross section flexible (fine-strand) 35 mm²
System configuration DC Yes
System configuration IT No
System configuration TN No
System configuration TN-C No
System configuration TN-S No
System configuration TT No
System configuration other No
System configuration TN-C-S No
Max. discharge surge current (8/20) 40 kA
Short-circuit breaking capacity (Isccr) 0 kA
Max. overcurrent protection device, parallel connection (fuse) 0 A
Max. overcurrent protection device, series connection (fuse) 0 A
Integrated short-circuit protection No
Integrated short-circuit protection selective to fuse gG 0 A
Leakage-current free No

Packing details

Packing level 1 3606480506673
Packing level 2 3606480506670
Packing level 3 3606480506671

Downloads

Description

This Acti9 iPRD-DC 40r direct current surge arresters protects 2P photovoltaic installations. It allows quick replacement of damaged cartridges. The Iscpv short circuit breaking capacity is 200A. The Itotal discharge current is 40kA. The In nominal discharge current is 15kA. This Type 2 device is recommended to protect against indirect lightning strikes. The surge arresters with r indication have remote transfer of the information Cartridge to be replaced. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The Uc maximum continuous operating voltage is 1000VDC. The Up protection level is 3.9kV in differential mode and in common mode. The dimensions are (W) 54mm x (H) 85mm x (D) 69mm. The width in 9mm pitches is 4. The weight is 400g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product complies with UTE C 61470-51 and EN 50539-11:2013 standards.