Register to unlock your exclusive B2B prices and start shopping. Sign up now!
MD01 image 1
iPRD40 modular surge arrester - 3P + N - 350V image 2
iPRD40 modular surge arrester - 3P + N - 350V image 3
iPRD40 modular surge arrester - 3P + N - 350V image 4
MD01 thumbnail 1
iPRD40 modular surge arrester - 3P + N - 350V thumbnail 2
iPRD40 modular surge arrester - 3P + N - 350V thumbnail 3
iPRD40 modular surge arrester - 3P + N - 350V thumbnail 4

iPRD40 modular surge arrester - 3P + N - 350V

In stock: No Vendor stock: Yes Minimal order quantity: 1
Price (excl. VAT):
78,15 €
This price is valid until 31.12.24
EAN: 3606480506383
MPN: A9L40600
Package: 1
Box: 3

Technical Information

Item condition New
Manufacture name iPRD40 modular surge arrester - 3P + N - 350V
Brand Schneider Electric
Categories Lighting protection
Country of origin CN
Harmonized System Code 8536 3030 99
Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact No
Number of conductors (without earthing) 4
Construction size 4 modular spacing
Voltage protection level 1.4 kV
Max. continuous voltage AC 350 V
Nominal discharge surge current (8/20) 15 kA
Nominal voltage AC 400 V
Nominal voltage DC 0 V
Category type 2 Yes
Voltage protection level L-N 1.4 kV
Signalling at the device Optic
Max. continuous voltage DC 0 V
Degree of protection (IP) IP20
Max. PV-voltage 0 V
Voltage protection level N-PE 1.4 kV
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 35 mm²
Max. conductor cross section flexible (fine-strand) 35 mm²
System configuration DC No
System configuration IT No
System configuration TN No
System configuration TN-C No
System configuration TN-S Yes
System configuration TT Yes
System configuration other No
System configuration TN-C-S No
Max. discharge surge current (8/20) 40 kA
Short-circuit breaking capacity (Isccr) 50 kA
Max. overcurrent protection device, parallel connection (fuse) 0 A
Max. overcurrent protection device, series connection (fuse) 0 A
Integrated short-circuit protection No
Integrated short-circuit protection selective to fuse gG 0 A
Leakage-current free No

Packing details

Packing level 1 3606480506383
Packing level 2 3606480506380
Packing level 3 3606480506381

Downloads

Description

This Acti9 iPRD40 surge arrester protects 3P+N installations. It allows quick replacement of damaged cartridges. This Type 2 device is recommended for high risk level and incoming panel board. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The associated circuit breaker Isc breaking capacity can go up to 50kA. This Acti9 iPRD40 is compatible with TT and TN-S earthing system. The Imax rated discharge current is 40kA. The In nominal discharge current is 15kA. The Uc maximum continuous operating voltage in common mode is 260VAC between neutral and earth, and 350VAC between phase and earth. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Up Voltage protection level is 1.4kV in common mode (N/PE) and in differential mode (L/N). The Un rated service voltage is 230VAC or 400VAC. The operating frequency is 50Hz or 60Hz. The dimensions are (W) 72mm x (H) 85mm x (D) 69mm. The width in 9mm pitches is 8. The weight is 450g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standards.