Item condition | New |
Manufacture name | iPRD40r modular surge arrester - 3P + N - 350V - with remote transfert |
Brand | Schneider Electric |
Categories |
Lighting protection
|
Country of origin | CN |
Harmonized System Code | 8536 3030 99 |
Mounting method | DIN rail (top hat rail) 35 mm |
With remote signalling contact | Yes |
Number of conductors (without earthing) | 4 |
Construction size | 4 modular spacing |
Voltage protection level | 1.4 kV |
Max. continuous voltage AC | 350 V |
Nominal discharge surge current (8/20) | 15 kA |
Nominal voltage AC | 400 V |
Nominal voltage DC | 0 V |
Category type 2 | Yes |
Voltage protection level L-N | 1.4 kV |
Signalling at the device | Optic |
Max. continuous voltage DC | 0 V |
Degree of protection (IP) | IP20 |
Max. PV-voltage | 0 V |
Voltage protection level N-PE | 1.4 kV |
Integrated backup fuse | No |
Max. conductor cross section solid (solid, stranded) | 25 mm² |
Max. conductor cross section flexible (fine-strand) | 16 mm² |
System configuration DC | No |
System configuration IT | No |
System configuration TN | No |
System configuration TN-C | No |
System configuration TN-S | Yes |
System configuration TT | Yes |
System configuration other | No |
System configuration TN-C-S | No |
Max. discharge surge current (8/20) | 40 kA |
Short-circuit breaking capacity (Isccr) | 50 kA |
Max. overcurrent protection device, parallel connection (fuse) | 0 A |
Max. overcurrent protection device, series connection (fuse) | 0 A |
Integrated short-circuit protection | No |
Integrated short-circuit protection selective to fuse gG | 0 A |
Leakage-current free | No |
Packing level 1 | 3606480506345 |
Packing level 2 | 3606480506342 |
Packing level 3 | 3606480506343 |
Packing level 4 | 3606480506345 |
This Acti9 iPRD40r surge arrester protects 3P+N installations. It allows quick replacement of damaged cartridges. This Type 2 device is recommended for high risk level in incoming panel board. It offers remote reporting of the "cartridge must be changed" message. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The associated circuit breaker Isc breaking capacity can go up to 50kA. It is compatible with TT and TN-S earthing system. The Imax rated discharge current is 40kA. The In nominal discharge current is 15kA. The Uc maximum continuous operating voltage in common mode is 260VAC between neutral and earth, and 350VAC between phase and earth. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Up Voltage protection level is 1.4kV in common mode (N/PE) and in differential mode (L/N). The Un rated service voltage is 230VAC or 400VAC. The operating frequency is 50Hz or 60Hz. The dimensions are (W) 72mm x (H) 85mm x (D) 69mm. The width in 9mm pitches is 8. The weight is 450g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standards.