Technical Information

Item condition New
Manufacture name iPRI signal protection - 4 poles - 0.3A - 48 V
Brand Schneider Electric
Categories Lighting protection
Country of origin DE
Harmonized System Code 8536 3010 90
Mounting method DIN rail (top hat rail) 35 mm
Connection 1 Other
Lightning impulse current (10/350 µs) 0 kA
With remote signalling contact No
Number of conductors (without earthing) 0
Limiting frequency 0.05 MHz
Explosion-tested version No
Max. continuous voltage AC 37 V
Nominal discharge surge current (8/20) 10 kA
Nominal load current 0.3 A
Voltage protection level core/core 70 V
Voltage protection level core/earth 70 V
Signalling at the device None
Max. continuous voltage DC 53 V
Degree of protection (IP) IP20
Voltage protection level core/signal ground 53 V
Voltage protection level signal ground/protective ground 37 V
Nominal voltage DC 48 V
Pro-active thermo-control Yes
Assembly width 0 mm
Earthing via Separate conductor

Packing details

Packing level 1 3606480383526
Packing level 2 3606480383524

Description

This Acti9 iPRI is a surge arrester protecting against overvoltage related to lightning strikes. It is an analogue telephone line protection. The iPRC surge arrester wired in series to the private installation input protects telephones, modems. The Uc maximum continuous operating voltage in common mode (between phase and earth) is 37 VAC or 53VDC. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 37VAC or 53VDC. The Up Voltage protection level is 70V in differential mode (between phase and neutral) and in common mode (between phase and earth). The Ue rated operational voltage is 48VDC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 18mm x (H) 90mm x (D) 66mm. The weight is 65g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C.