Technical Information
Item condition |
New |
Manufacture name |
KNX bl.sw.act.REG-K/8x/16 /10 w.man.mode |
Brand |
Schneider Electric
|
Categories |
Sensors
|
Country of origin |
DE |
Mounting method |
DRA (DIN-rail adapter) |
Type of current |
AC |
Number of inputs |
0 |
Bus system KNX |
Yes |
Bus system radio frequent |
No |
Bus system Powernet |
No |
Max. switching power |
2000 W |
With bus connection |
Yes |
Max. number of venetian-blind outputs |
8 |
Switching current (resistive) |
10 A |
Width in number of modular spacings |
8 |
Other bus systems |
None |
Bus system LON |
No |
Local operation/hand operation |
Yes |
With switch function |
Yes |
Degree of protection (IP) |
IP20 |
With LED indication |
Yes |
Bus system KNX radio |
No |
Radio frequent bidirectional |
No |
Bus module detachable |
No |
Min. depth of built-in installation box |
0 mm |
Packing details
Packing level 1 |
3606485012018 |
Packing level 2 |
3606485012016 |
Description
For independent control of up to 8 blind/roller shutter drives or for switching up to 16 loads via make contacts. The function of the blind or switching channels is freely configurable. All blind/switch outputs can be operated manually using push-buttons. The bus is connected using a bus connecting terminal. A data rail is not necessary. Channel status display via LEDs. A green LED indicates readiness for operation. With integrated bus coupler. For installation on DIN rails TH35 according to EN 60715. The bus is connected using a bus connecting terminal. a data rail is not necessary. Blind functions: Blind type. Running time. Idle time. Step interval. Weather alarm. 8-bit positioning for height and slats. Scenes. Status and feedback function. Switch actuator functions: Operation as break contact/make contact. Programmable behaviour for download. Delay functions for each channel. Staircase lighting function with/without manual OFF function. Cut-out warning for staircase lighting function. Scenes. Central function. Disable function. Logic operation or priority control. Status feedback function for each channel. Nominal voltage: AC 100-240 V ±10%. Operating voltage: min. AC 90 V - max. AC 265 V. Mains frequency: 50-60 Hz ±10%. For each blind output: Nominal current: 10 A, inductive load cos Phi 0.6. Motor load: AC 100 V, max. 434 W. AC 230 V, max. 1000 W. AC 240 V, max. 1043 W. For each switch output: Nominal current: 10 A, ohmic load cos Phi 1. 10 A, inductive load cos Phi 0.6. Nominal load. Incandescent lamps: AC 100 V, max. 869 W. AC 230 V, max. 2000 W. AC 240 V, max. 2086 W. Halogen lamps: AC 100 V, max. 739 W. AC 230 V, max. 1700 W. AC 240 V, max. 1773 W. Fluorescent lamps: AC 100 V, max. 434 VA.AC 230 V, max. 1000 VA. AC 240 V, max. 1043 VA. parallel-compensated. Capacitive load: AC 230 V, 10 A, max. 105 µF. External auxiliary voltage: Nominal voltage: AC 110-240 V ±10%. Device width: 8 modules, approx. 144 mm. Contents: With bus connecting terminal and cable cover. Colour: light grey.