Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Lightning current / surge arresters, pluggable, 600 VDC, 2-pole+PE, earthed image 1
Lightning current / surge arresters, pluggable, 600 VDC, 2-pole+PE, earthed image 2
Lightning current / surge arresters, pluggable, 600 VDC, 2-pole+PE, earthed image 3
Lightning current / surge arresters, pluggable, 600 VDC, 2-pole+PE, earthed image 4
Lightning current / surge arresters, pluggable, 600 VDC, 2-pole+PE, earthed image 5
Lightning current / surge arresters, pluggable, 600 VDC, 2-pole+PE, earthed image 6
Lightning current / surge arresters, pluggable, 600 VDC, 2-pole+PE, earthed thumbnail 1
Lightning current / surge arresters, pluggable, 600 VDC, 2-pole+PE, earthed thumbnail 2
Lightning current / surge arresters, pluggable, 600 VDC, 2-pole+PE, earthed thumbnail 3
Lightning current / surge arresters, pluggable, 600 VDC, 2-pole+PE, earthed thumbnail 4
Lightning current / surge arresters, pluggable, 600 VDC, 2-pole+PE, earthed thumbnail 5
Lightning current / surge arresters, pluggable, 600 VDC, 2-pole+PE, earthed thumbnail 6

Lightning current / surge arresters, pluggable, 600 VDC, 2-pole+PE, earthed

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
124,33 €
This price is valid until 24.12.24
EAN: 4015081717101
MPN: 177258
Package: 1
Box: 100

Technical Information

Item condition New
Manufacture name Lightning current / surge arresters, pluggable, 600 VDC, 2-pole+PE, earthed
Brand EATON
Categories Lighting protection
Country of origin DE
Harmonized System Code 8536 5080 00
Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact No
Number of conductors (without earthing) 2
Construction size 3 modular spacing
Voltage protection level 2.6 kV
Max. continuous voltage AC 0 V
Nominal discharge surge current (8/20) 15 kA
Nominal voltage AC 0 V
Nominal voltage DC 600 V
Category type 2 Yes
Voltage protection level L-N 0 kV
Signalling at the device Optic
Max. continuous voltage DC 720 V
Degree of protection (IP) IP20
Max. PV-voltage 720 V
Voltage protection level N-PE 0 kV
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 0 mm²
Max. conductor cross section flexible (fine-strand) 0 mm²
System configuration DC No
System configuration IT Yes
System configuration TN No
System configuration TN-C No
System configuration TN-S No
System configuration TT No
System configuration other No
System configuration TN-C-S No
Max. discharge surge current (8/20) 40 kA
Short-circuit breaking capacity (Isccr) 0 kA
Max. overcurrent protection device, parallel connection (fuse) 0 A
Max. overcurrent protection device, series connection (fuse) 0 A
Integrated short-circuit protection No
Integrated short-circuit protection selective to fuse gG 0 A
Leakage-current free No