Register to unlock your exclusive B2B prices and start shopping. Sign up now!
MD01 image 1
Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic, Everlink terminals image 2
Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic, Everlink terminals image 3
Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic, Everlink terminals image 4
MD01 thumbnail 1
Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic, Everlink terminals thumbnail 2
Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic, Everlink terminals thumbnail 3
Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic, Everlink terminals thumbnail 4

Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic, Everlink terminals

In stock: No Vendor stock: Yes Minimal order quantity: 1
Price (excl. VAT):
110,95 €
This price is valid until 24.12.24
EAN: 3606481310071
MPN: GV4PE25B
Package: 1
Box: 5

Technical Information

Item condition New
Manufacture name Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 25kA, thermal magnetic, Everlink terminals
Brand Schneider Electric
Categories Motor protection circuit-breakers
Country of origin PL
Harmonized System Code 8536 2010 90
Width 81 mm
Height 155 mm
Depth 116 mm
Rated operation power at AC-3, 400 V 11 kW
With integrated auxiliary switch No
Rated permanent current Iu 25 A
With integrated under voltage release No
Number of poles 3
Rated operating voltage 0-690 V
Overload release current setting 10-25 A
Degree of protection (IP) IP40
With thermal protection Yes
Type of electrical connection of main circuit Screw connection
Type of control element Rocker lever
Switch off technique Electronic
Rated operation power at AC-3, 230 V 5.5 kW
Rated short-circuit breaking capacity lcu at 400 V, AC 25 kA
Adjustment range undelayed short-circuit release 425 A
Phase failure sensitive Yes
Device construction Complete device in housing

Packing details

Packing level 1 3606481310071
Packing level 2 3606481310079

Downloads

Description

TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for protection of 3-phase motors 5.5-11kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 25kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 10-25A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).