Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Mains monitoring relay monitoring the rotating field, 1 CO contact 10A image 1

Mains monitoring relay monitoring the rotating field, 1 CO contact 10A

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
39,26 €
This price is valid until 31.12.24
EAN: 4010312202524
MPN: 22001330
Package: 1

Technical Information

Item condition New
Manufacture name Mains monitoring relay monitoring the rotating field, 1 CO contact 10A
Brand ELTAKO
Categories Relays
Country of origin CN
Harmonized System Code 8536 4900 00
Width 18 mm
Height 58 mm
Depth 58 mm
Voltage measuring range 230 V
With detachable clamps No
Phase sequence monitoring Yes
Phase failure detection Yes
Function under voltage detection Yes
Function over voltage detection Yes
Phase imbalance monitoring No
Type of electric connection Screw connection
Rated control supply voltage at AC 50 Hz 250 V
Rated control supply voltage at AC 60 Hz 250 V
Max. permitted off-delay time 8 s
Min. adjustable off-delay time 0.1 s
Voltage type for actuating AC
Number of contacts as normally closed contact 0
Number of contacts as normally open contact 0
Number of contacts as change-over contact 1

Packing details

Packing level 1 4010312202524, 4010312202524
Packing level 2 4010312202524
Packing level 3 4010312202524

Downloads

Description

1 CO contact potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamp load 2000W. Standby loss 0.8 watt only. Modular device for DIN 60715 TH35 rail mounting. 1 module =18mm wide, 58mm deep. Designed to monitor 230V AC voltage between 1 to 3 phase conductors and neutral and to monitor the rotating field (clockwise) in the switch positions 2Ph and 3Ph. In the position rotating field only the rotating field is monitored, independent from the mains voltage. Supply voltage L1-N 180-250V/50Hz. In case of failure of L1 the relay releases immediately without delay. With the lower rotary switch on the front two operate voltages resp. dropout voltages can be set and the number of monitored phase conductors must be selected. U1: 161V dropout voltage and 185V operate voltage. U2: 196V dropout voltage and 206V operate voltage as per VDE 0100, part 718 (formerly: VDE 0108, part 1). Voltage applied signalled by LED. At wrong polarity or in case of a missing phase conductor the LED flashes rapidly. Release delay RV settable with the upper rotary switch from 0.1 to 8sec. The LED flashes slowly during the release delay time period. Operate delay 0.5sec. Maximum fusing 16A.