Register to unlock your exclusive B2B prices. Register now
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 90 image 1
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 90 image 2
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 90 image 3
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 90 image 4
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 90 image 5
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 90 image 6
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 90 image 7
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 90 image 8
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 90 image 9
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 90 image 10
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 90 image 11

NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 90

In stock price (excl. VAT):
978,83 €
This price is valid until 2024-12-31
Price per m: 978,83 €
EAN: 4015081876952
MPN: 189702
Our warehouse: No Vendor stock: No
Per package: 1 Per box: N/A
Technical data
Item condition New
Manufacture name NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 90
Brand EATON
Categories Motor protection circuit-breakers
Country of origin RO
Harmonized System Code 8536 2090 00
Width 105 mm
Height 149 mm
Depth 184 mm
Rated operation power at AC-3, 400 V 45 kW
With integrated auxiliary switch No
Rated permanent current Iu 90 A
With integrated under voltage release No
Number of poles 3
Rated operating voltage 690 V
Overload release current setting 36-90 A
Degree of protection (IP) IP20
With thermal protection Yes
Type of electrical connection of main circuit Screw connection
Type of control element Rocker lever
Switch off technique Electronic
Rated operation power at AC-3, 230 V 22 kW
Rated short-circuit breaking capacity lcu at 400 V, AC 130 kA
Adjustment range undelayed short-circuit release 180-1620 A
Phase failure sensitive Yes
Device construction Built-in device fixed built-in technique
Packing details
Packing level 1 4015081876952
Description
Circuit-breaker, Motor protection, IEC, Fixed, Electronic release, IEC/EN 60947-4-1, IEC/EN 60947-2, The circuit-breaker fulfills all requirements for AC-3 switching category., R.m.s. value measurement and “thermal memory”, adjustable time delay setting to overcome current peaks tr: 2 – 20 s at 6 x Ir also infinity (without overload releases), All AC-3 rating data applies to direct switching by the circuit-breaker under normal operating conditions . If, for example, a contactor takes over AC-3 switching under normal operating conditions, the full rated uninterrupted current applies to the circuit-breaker, In = Iu., 3 pole, Screw terminal, Rated current = rated uninterrupted current: In = Iu 90 A, Ii = In x … 2 - 14