NZM4 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 4p, variable, Screw terminal, earth-fault protection, ARMS and zone selectiv image 1
NZM4 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 4p, variable, Screw terminal, earth-fault protection, ARMS and zone selectiv image 2
NZM4 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 4p, variable, Screw terminal, earth-fault protection, ARMS and zone selectiv image 3
NZM4 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 4p, variable, Screw terminal, earth-fault protection, ARMS and zone selectiv image 4
NZM4 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 4p, variable, Screw terminal, earth-fault protection, ARMS and zone selectiv image 5
NZM4 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 4p, variable, Screw terminal, earth-fault protection, ARMS and zone selectiv image 6
NZM4 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 4p, variable, Screw terminal, earth-fault protection, ARMS and zone selectiv image 7
NZM4 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 4p, variable, Screw terminal, earth-fault protection, ARMS and zone selectiv thumbnail 1
NZM4 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 4p, variable, Screw terminal, earth-fault protection, ARMS and zone selectiv thumbnail 2
NZM4 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 4p, variable, Screw terminal, earth-fault protection, ARMS and zone selectiv thumbnail 3
NZM4 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 4p, variable, Screw terminal, earth-fault protection, ARMS and zone selectiv thumbnail 4
NZM4 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 4p, variable, Screw terminal, earth-fault protection, ARMS and zone selectiv thumbnail 5
NZM4 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 4p, variable, Screw terminal, earth-fault protection, ARMS and zone selectiv thumbnail 6
NZM4 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 4p, variable, Screw terminal, earth-fault protection, ARMS and zone selectiv thumbnail 7

NZM4 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 4p, variable, Screw terminal, earth-fault protection, ARMS and zone selectiv

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
4 287,57 €
This price is valid until 24.12.24
EAN: 4015081876037
MPN: 189656
Package: 1

Technical Information

Item condition New
Manufacture name NZM4 PXR25 circuit breaker - integrated energy measurement class 1, 630A, 4p, variable, Screw terminal, earth-fault protection, ARMS and zone selectiv
Brand EATON
Categories Breakers
Country of origin RO
Harmonized System Code 8536 2090 00
Number of auxiliary contacts as normally open contact 0
Number of auxiliary contacts as normally closed contact 0
Rated permanent current Iu 630 A
With integrated under voltage release No
Number of poles 4
Overload release current setting 252-630 A
Number of auxiliary contacts as change-over contact 0
Rated voltage 690 V
Degree of protection (IP) IP20
Position of connection for main current circuit Front side
Motor drive integrated No
Type of electrical connection of main circuit Screw connection
Type of control element Rocker lever
With switched-off indicator No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz 50 kA
Adjustment range short-term delayed short-circuit release 2-10 A
Adjustment range undelayed short-circuit release 1260-22680 A
Suitable for DIN rail (top hat rail) mounting No
Integrated earth fault protection Yes
Motor drive optional Yes
Device construction Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional No
Complete device with protection unit Yes

Packing details

Packing level 1 4015081876037

Description

The xEffect NZM...-PX...-TAZ circuit breaker range with power expert release (PXR) electronic triggering system covers use cases for full range protection including earth fault protection with only four compact sizes and is suitable for the IEC market. The integrated energy measuring function supplies currents, voltages and active energy (kWh) with accuracy class 1 according to IEC 61557-12. Maintenance mde ARMS and zone selectivity for extended protection included. Test function and settings via micro USB port directly on the switch . Modular function groups always make mounting flexible and may be supplemented by the comprehensive range of accessories. R.m.s. value measurement and thermal memory.

Similar items

Accessories

Similar items

Suitable for

Similar items
4015082666187 4015082666842 4015082666859 4015082666910 4015082666927 4015082667146 4015082668372 4015082856045 4015082856021 4015082855574
Accessories
4015082666187 4015082666842 4015082666859 4015082666910 4015082666927 4015082667146 4015082668372 4015082856045 4015082856021 4015082855574
Similar items
4015082666149 4015082856038 4015082601546 4015082667146 4015082856045 4015082294137 4015082664510 4015082666927 4015082666163 4015082661939
Suitable for
4015082666842 4015082666859 4015082666910 4015082666927 4015082667146 4015082668372 4015082856038 4015082856045 4015082856021 4015082855574