Register to unlock your exclusive B2B prices and start shopping. Sign up now!
OVR PV T2 40-1000 P TS Surge Protective Device image 1
MD01 image 2
MD99 image 3
MD99 image 4
MD01 image 5
MD01 image 6
MD99 image 7
MD99 image 8
MD99 image 9
MD99 image 10
OVR PV T2 40-1000 P TS Surge Protective Device image 11
OVR PV T2 40-1000 P TS Surge Protective Device thumbnail 1
MD01 thumbnail 2
MD99 thumbnail 3
MD99 thumbnail 4
MD01 thumbnail 5
MD01 thumbnail 6
MD99 thumbnail 7
MD99 thumbnail 8
MD99 thumbnail 9
MD99 thumbnail 10
OVR PV T2 40-1000 P TS Surge Protective Device thumbnail 11

OVR PV T2 40-1000 P TS Surge Protective Device

In stock: No Vendor stock: Yes Minimal order quantity: 1
Price (excl. VAT):
90,95 € per pcs
This price is valid until 24.12.24
EAN: 4053546050165
MPN: 2CTB802401R1000
Box: 1

Technical Information

Item condition New
Manufacture name OVR PV T2 40-1000 P TS Surge Protective Device
Brand ABB
Categories Lighting protection
Harmonized System Code 8536 9095 00
Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact Yes
Number of conductors (without earthing) 2
Construction size 3 modular spacing
Voltage protection level 3 kV
Max. continuous voltage AC 1000 V
Nominal discharge surge current (8/20) 20 kA
Nominal voltage DC 1000 V
Category type 2 Yes
Signalling at the device None
Max. continuous voltage DC 1000 V
Degree of protection (IP) IP20
Max. PV-voltage 1000 V
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 35 mm²
Max. conductor cross section flexible (fine-strand) 25 mm²
System configuration DC Yes
System configuration IT No
System configuration TN No
System configuration TN-C No
System configuration TN-S No
System configuration TT No
System configuration other No
System configuration TN-C-S No
Max. discharge surge current (8/20) 40 kA
Short-circuit breaking capacity (Isccr) 10 kA
Integrated short-circuit protection No
Leakage-current free No

Packing details

Packing level 1 4053546050165

Downloads

Description

Überspannungs-Schutzeinrichtung OVR PV T2 schützen elektrische Anlagen vor Überspannungen. Sie sind nach IEC 61643-31, DIN EN 50539-11 und UL 1449 5th Ed Typ 2 geprüft. Der Status der Überspannungs-Schutzeinrichtung erfolgt über eine Funktionsanzeige. OVR mit Telesignal "TS" sind optional mit einem potentialfreien Wechselkontakt ausgestattet und können den Staus zum Beispiel an ein Monitoring-System weitermelden. Die Anwendung ist speziell auf der DC-Seite von Photovoltaik-Anlagen.