Register to unlock your exclusive B2B prices and start shopping. Sign up now!
OVR PV T1-T2 10-1500 P TS QS Surge Protective Device image 1
OVR PV T1-T2 10-1500 P TS QS Surge Protective Device image 2
OVR PV T1-T2 10-1500 P TS QS Surge Protective Device thumbnail 1
OVR PV T1-T2 10-1500 P TS QS Surge Protective Device thumbnail 2

OVR PV T1-T2 10-1500 P TS QS Surge Protective Device

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
109,34 € per pcs
This price is valid until 01.01.25
EAN: 4053546034691
MPN: 2CTB812101R1500
Box: 1

Technical Information

Item condition New
Manufacture name OVR PV T1-T2 10-1500 P TS QS Surge Protective Device
Brand ABB
Categories Lighting protection
Harmonized System Code 8536 9095 00
Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact Yes
Number of conductors (without earthing) 2
Construction size 3 modular spacing
Voltage protection level 5 kV
Max. continuous voltage AC 1500 V
Nominal discharge surge current (8/20) 20 kA
Nominal voltage DC 1500 V
Category type 2 Yes
Voltage protection level L-N 5 kV
Signalling at the device None
Max. continuous voltage DC 1500 V
Degree of protection (IP) IP20
Max. PV-voltage 1500 V
Voltage protection level N-PE 5 kV
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 35 mm²
Max. conductor cross section flexible (fine-strand) 25 mm²
System configuration DC Yes
System configuration IT No
System configuration TN No
System configuration TN-C No
System configuration TN-S No
System configuration TT No
System configuration other No
System configuration TN-C-S No
Max. discharge surge current (8/20) 40 kA
Short-circuit breaking capacity (Isccr) 11 kA
Max. overcurrent protection device, parallel connection (fuse) 0 A
Max. overcurrent protection device, series connection (fuse) 10 A
Integrated short-circuit protection No
Integrated short-circuit protection selective to fuse gG 0 A
Leakage-current free No

Packing details

Packing level 1 4053546034691
Packing level 2 4053546034691

Downloads

Description

Überspannungs-Schutzeinrichtung OVR PV T1-T2 schützen elektrische Anlagen vor Blitz-Überspannungen. Sie sind nach IEC 61643-31, DIN EN 50539-11 und UL 1449 Typ 1+2 geprüft. Der Status der Überspannungs-Schutzeinrichtung erfolgt über eine mechanische Funktionsanzeige. OVR mit Telesignal "TS" sind optional mit einem potentialfreien Wechselkontakt ausgestattet und können den Staus zum Beispiel an ein Monitoring-System weitermelden. Die Anwendung ist speziell auf der DC-Seite von Photovoltaik-Anlagen.