Register to unlock your exclusive B2B prices and start shopping. Sign up now!
OVR T2 N3 40-440 P TS QS Surge Protective Device image 1
OVR T2 N3 40-440 P TS QS Surge Protective Device image 2
OVR T2 N3 40-440 P TS QS Surge Protective Device image 3
OVR T2 N3 40-440 P TS QS Surge Protective Device image 4
OVR T2 N3 40-440 P TS QS Surge Protective Device image 5
OVR T2 N3 40-440 P TS QS Surge Protective Device image 6
OVR T2 N3 40-440 P TS QS Surge Protective Device thumbnail 1
OVR T2 N3 40-440 P TS QS Surge Protective Device thumbnail 2
OVR T2 N3 40-440 P TS QS Surge Protective Device thumbnail 3
OVR T2 N3 40-440 P TS QS Surge Protective Device thumbnail 4
OVR T2 N3 40-440 P TS QS Surge Protective Device thumbnail 5
OVR T2 N3 40-440 P TS QS Surge Protective Device thumbnail 6

OVR T2 N3 40-440 P TS QS Surge Protective Device

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
210,50 € per pcs
This price is valid until 24.12.24
EAN: 3660308520104
MPN: 2CTB803873R1600
Package: 1

Technical Information

Item condition New
Manufacture name OVR T2 N3 40-440 P TS QS Surge Protective Device
Brand ABB
Categories Lighting protection
Harmonized System Code 8536 3090 00
Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact Yes
Number of conductors (without earthing) 4
Construction size 4 modular spacing
Voltage protection level 2.1 kV
Max. continuous voltage AC 440 V
Nominal discharge surge current (8/20) 20 kA
Nominal voltage AC 690 V
Nominal voltage DC 0 V
Category type 2 Yes
Voltage protection level L-N 1.8 kV
Signalling at the device Optic
Max. continuous voltage DC 560 V
Degree of protection (IP) IP20
Max. PV-voltage 0 V
Voltage protection level N-PE 1.4 kV
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 25 mm²
Max. conductor cross section flexible (fine-strand) 16 mm²
System configuration DC No
System configuration IT No
System configuration TN Yes
System configuration TN-C No
System configuration TN-S Yes
System configuration TT Yes
System configuration other No
System configuration TN-C-S Yes
Max. discharge surge current (8/20) 40 kA
Short-circuit breaking capacity (Isccr) 100 kA
Max. overcurrent protection device, parallel connection (fuse) 0 A
Max. overcurrent protection device, series connection (fuse) 125 A
Integrated short-circuit protection No
Integrated short-circuit protection selective to fuse gG 125 A
Leakage-current free Yes

Packing details

Packing level 1 3660308520104

Downloads

Description

OVR T2 N3 40-440 P QS Surge Protective Device