Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Residual-current circuit breaker trip block for PLS. 40A, 4 p, 300mA, type S image 1
Residual-current circuit breaker trip block for PLS. 40A, 4 p, 300mA, type S image 2
Residual-current circuit breaker trip block for PLS. 40A, 4 p, 300mA, type S image 3
Residual-current circuit breaker trip block for PLS. 40A, 4 p, 300mA, type S image 4
Residual-current circuit breaker trip block for PLS. 40A, 4 p, 300mA, type S thumbnail 1
Residual-current circuit breaker trip block for PLS. 40A, 4 p, 300mA, type S thumbnail 2
Residual-current circuit breaker trip block for PLS. 40A, 4 p, 300mA, type S thumbnail 3
Residual-current circuit breaker trip block for PLS. 40A, 4 p, 300mA, type S thumbnail 4

Residual-current circuit breaker trip block for PLS. 40A, 4 p, 300mA, type S

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
54,13 €
This price is valid until 24.12.24
EAN: 4015082669751
MPN: 266975
Package: 1
Box: 13

Technical Information

Item condition New
Manufacture name Residual-current circuit breaker trip block for PLS. 40A, 4 p, 300mA, type S
Brand EATON
Categories Accessories (Automatics & control)
Country of origin CZ
Harmonized System Code 8536 2010 00
Nominal current 40 A
Rated insulation voltage Ui 440 V
Number of poles 4
Delay adjustable No
Max. delay time 40 ms
Leakage current type AC
Surge current capacity 5 kA
Pollution degree 2
Rated fault current 0.3 A
Nominal voltage 240-415 V
Frequency 50 Hz
Degree of protection (IP) IP20
Connectable conductor cross section solid-core 0.75-35 mm²
Connectable conductor cross section multi-wired 0.75-35 mm²
With interlocking device Yes
Ambient temperature during operating -25-40 °C
Rated fault current adjustable No
Anti-nuisance tripping version No
Rated impulse withstand voltage Uimp 4 kV

Packing details

Packing level 1 4015082669751
Packing level 2 9007912332374

Description

High-quality residual current circuit-breaker/miniature circuit-breaker with overcurrent protection independent of mains voltage, contact position display red-green, terminal rear plug protection, tri-stable slide catch—enables removal from an existing closure assembly, comprehensive accessory product range can be retrofitted, wide range of rated fault currents, rated operational currents up to 40 A, trip types B, Cc, D, rated switching capacity 10 kA, suitable for use in the free (on-site power and outdoor distribution board) to -25 °C