Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Phase monitoring relays, On- and Off-delayed, 380 V AC, 50/60 Hz image 1
Phase monitoring relays, On- and Off-delayed, 380 V AC, 50/60 Hz image 2
Phase monitoring relays, On- and Off-delayed, 380 V AC, 50/60 Hz image 3
Phase monitoring relays, On- and Off-delayed, 380 V AC, 50/60 Hz image 4
Phase monitoring relays, On- and Off-delayed, 380 V AC, 50/60 Hz thumbnail 1
Phase monitoring relays, On- and Off-delayed, 380 V AC, 50/60 Hz thumbnail 2
Phase monitoring relays, On- and Off-delayed, 380 V AC, 50/60 Hz thumbnail 3
Phase monitoring relays, On- and Off-delayed, 380 V AC, 50/60 Hz thumbnail 4

Phase monitoring relays, On- and Off-delayed, 380 V AC, 50/60 Hz

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
106,08 €
This price is valid until 24.12.24
EAN: 4015081788132
MPN: 184777
Package: 1

Technical Information

Item condition New
Manufacture name Phase monitoring relays, On- and Off-delayed, 380 V AC, 50/60 Hz
Brand EATON
Categories Relays
Country of origin DE
Harmonized System Code 8536 4900 00
Width 22.5 mm
Height 85.6 mm
Depth 103.7 mm
Voltage measuring range 380 V
With detachable clamps No
Phase sequence monitoring Yes
Phase failure detection Yes
Function under voltage detection Yes
Function over voltage detection Yes
Phase imbalance monitoring No
Type of electric connection Screw connection
Rated control supply voltage at AC 50 Hz 380 V
Rated control supply voltage at AC 60 Hz 380 V
Rated control supply voltage at DC 0 V
Max. permitted delay-on energization time 30 s
Min. adjustable delay-on energization time 0.1 s
Max. permitted off-delay time 30 s
Min. adjustable off-delay time 0.1 s
Voltage type for actuating AC
Number of contacts as normally closed contact 0
Number of contacts as normally open contact 0
Number of contacts as change-over contact 2

Packing details

Packing level 1 4015081788132

Description

Phase monitoring relays, Product range: EMR Measuring and monitoring relays, On- and Off-delayed, Power supply from the measuring circuit, On-delay/off-delay: none = 0 or adjustable between 0.1 - 30 s, Imbalance threshold values adjustable 2 - 25 % of mean value of phase voltages, Three-phase networks, Monitoring voltage per phase: UN= 380 V AC, 50/60 Hz V AC, Monitoring of: Phase sequence (can be deactivated), Phase failure, Overvoltage, Undervoltage, Supply voltage: 380 V, 50/60 Hz, Mounting position: As required, Fixing: Snap fixing, top-hat rail IEC/EN 60715, Width: 22.5 mm, Standards: IEC, UL, CSA, CCC, GL