Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Residual current circuit-breaker, all-current sensitive, 80 A, 4p, 100 mA, type B image 1
Residual current circuit-breaker, all-current sensitive, 80 A, 4p, 100 mA, type B image 2
Residual current circuit-breaker, all-current sensitive, 80 A, 4p, 100 mA, type B image 3
Residual current circuit-breaker, all-current sensitive, 80 A, 4p, 100 mA, type B image 4
Residual current circuit-breaker, all-current sensitive, 80 A, 4p, 100 mA, type B image 5
Residual current circuit-breaker, all-current sensitive, 80 A, 4p, 100 mA, type B image 6
Residual current circuit-breaker, all-current sensitive, 80 A, 4p, 100 mA, type B thumbnail 1
Residual current circuit-breaker, all-current sensitive, 80 A, 4p, 100 mA, type B thumbnail 2
Residual current circuit-breaker, all-current sensitive, 80 A, 4p, 100 mA, type B thumbnail 3
Residual current circuit-breaker, all-current sensitive, 80 A, 4p, 100 mA, type B thumbnail 4
Residual current circuit-breaker, all-current sensitive, 80 A, 4p, 100 mA, type B thumbnail 5
Residual current circuit-breaker, all-current sensitive, 80 A, 4p, 100 mA, type B thumbnail 6

Residual current circuit-breaker, all-current sensitive, 80 A, 4p, 100 mA, type B

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
1 570,56 €
This price is valid until 24.12.24
EAN: 4015081854912
MPN: 187807
Package: 1
Box: 30

Technical Information

Item condition New
Manufacture name Residual current circuit-breaker, all-current sensitive, 80 A, 4p, 100 mA, type B
Brand EATON
Categories Leakage protection
Country of origin DE
Harmonized System Code 8536 2090 00
Mounting method DIN rail
Voltage type AC
Built-in depth 77.5 mm
Rated current 80 A
Rated voltage 240 V
Rated insulation voltage Ui 440 V
Number of poles 4
Rated fault current 0.1 A
Leakage current type B
Selective protection No
Short-circuit breaking capacity (Icw) 10 kA
Surge current capacity 3 kA
Pollution degree 2
Width in number of modular spacings 4
Short-time delayed tripping No
Explosion-proof No
Frequency 50 Hz
Degree of protection (IP) IP20
Connectable conductor cross section solid-core 1.5-50 mm²
Connectable conductor cross section multi-wired 1.5-16 mm²
With interlocking device Yes
Ambient temperature during operating -25-75 °C
Additional equipment possible Yes
Rated impulse withstand voltage Uimp 4 kV

Packing details

Packing level 1 4015081854912
Packing level 2 9008790853890

Description

Residual current circuit-breaker, 4 pole, Rated current In: 80 A, Rated short-circuit strength Icn: 10 with back-up fuse kA, Rated fault current IΔN: 0.1 A