Register to unlock your exclusive B2B prices. Register now
RCD/MCB combination, 20 A, 100 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 1
RCD/MCB combination, 20 A, 100 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 2
RCD/MCB combination, 20 A, 100 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 3
RCD/MCB combination, 20 A, 100 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 4
RCD/MCB combination, 20 A, 100 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 5
RCD/MCB combination, 20 A, 100 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 6
RCD/MCB combination, 20 A, 100 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 7
RCD/MCB combination, 20 A, 100 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 8
RCD/MCB combination, 20 A, 100 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 9
RCD/MCB combination, 20 A, 100 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 10
RCD/MCB combination, 20 A, 100 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 11
RCD/MCB combination, 20 A, 100 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 12
RCD/MCB combination, 20 A, 100 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A image 13

RCD/MCB combination, 20 A, 100 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A

In stock price (excl. VAT):
68,19 €
This price is valid until 2024-12-31
Price per m: 68,19 €
EAN: 4015081077700
MPN: 108116
Our warehouse: No Vendor stock: No
Per package: 1 Per box: 60 Per pallet: N/A
Technical data
Item condition New
Manufacture name RCD/MCB combination, 20 A, 100 mA, MCB trip characteristic: B, 2p, RCD trip characteristic: A
Brand EATON
Categories Leakage protection
Country of origin RO
Harmonized System Code 8536 2010 00
Voltage type AC
Built-in depth 70.000 mm
Rated current 20.000 A
Rated voltage 230.000 V
Release characteristic B
Rated insulation voltage Ui 250.000 V
Rated fault current 0.100 A
Leakage current type A
Surge current capacity 0.250 kA
Current limiting class 3.000
Over voltage category 3.000
Pollution degree 2.000
Width in number of modular spacings 2.000
Frequency 50 Hz
Degree of protection (IP) IP20
Number of protected poles 2.000
Concurrently switching neutral conductor No
Rated short-circuit breaking capacity according to IEC 60947-2 0.000 kA
Connectable conductor cross section solid-core 1.000-25.000 mm²
Connectable conductor cross section multi-wired 1.000-25.000 mm²
With interlocking device No
Ambient temperature during operating -25.000-40.000 °C
Flush-mounted installation No
Number of poles (total) 2.000
Anti-nuisance tripping version No
Rated impulse withstand voltage Uimp 4.000 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1 10.000 kA
Disconnection characteristic Undelayed
Rated short-circuit breaking capacity according to EN 61009 10.000 kA
Packing details
Packing level 1 4015081077700
Packing level 2 9007912825234
Description
High-quality residual current device/miniature circuit breaker combination, line voltage-independent, contact position indicator red - green, terminal rear plug protection, tri-stable slide catch - enables removal from existing busbar system, comprehensive range of accessories suitable for subsequent installation, wide range of rated fault currents, rated operational currents up to 40 A, tripping characteristics B, C, D, rated breaking capacity 10 kA, suitable for outdoor use (on-site power and outdoor distribution board) up to -25 °C