Item condition |
New |
Manufacture name |
Round cable, SmartWire-DT, 250m, 8-Pole, 8mm |
Brand |
EATON
|
Categories |
Ethernet cable (network)
|
Country of origin |
DE |
Harmonized System Code |
8544 4993 00
|
UV resistant |
Yes |
Nominal cross section conductor |
0.5 mm² |
Material core insulation |
Other |
Core identification |
Colour |
Weight |
20 kg/km |
Flame retardant |
According to IEC/EN 60332-1-2 |
Drain wire |
No |
Circuit integrity |
None |
Stranding element |
Pairs |
Colour outer sheath |
Green |
Category |
Other |
Diameter conductor |
1.5 mm |
Conductor material |
Other |
Screen over stranding element |
Foil |
Screen over stranding |
None |
Material outer sheath |
Polyvinyl chloride (PVC) |
Conductor category |
Class 2 = stranded |
Armouring/reinforcement |
None |
Permitted cable outer temperature during assembling/handling |
-10-80 °C |
Permitted cable outer temperature after assembling without vibration |
-20-80 °C |
Number of stranding elements |
4 |
Protective sheath |
Other |
Number of cores |
8 |
Suitable for underground installation |
No |
Halogen free according to IEC 60754-2 |
No |
Insulation integrity according to IEC 60331 |
No |
Cable height approx. |
400 |
Low smoke according to IEC 61034-2 |
No |
Stranding |
Bundle |
Outer diameter approx. |
8.2 mm |
With rodent protection |
No |
Low smoke (according to EN 61034-2) |
No |
NVP value |
66.5 % |
Halogen free according to EN 60754-1/2 |
No |
Oil resistant according to IEC 60811-404 |
Yes |
Oil resistant (according to IEC 60811-404) |
Yes |
Conductor surface |
Bare |
Longitudinal water blocking cable |
Yes |
Radial water blocking cable |
No |
Reaction-to-fire according to EN 13501-6: Class |
None |
Reaction-to-fire according to EN 13501-6: Smoke production |
None |
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles |
None |
Reaction-to-fire according to EN 13501-6: Acidity |
None |
AWG size |
20 |
Min. permitted bending radius, moving application with forced guidance |
120 mm |
Min. permitted bending radius, moving application/free movement |
120 mm |
Min. permitted bending radius, stationary application/permanent installation |
120 mm |
Specification core insulation |
Other |
Specification material outer sheath |
Other |
Material reinforcement |
Other |
Cable geometry |
Round |
Core identification according to HD 308 S2 |
No |
Suitable as telephone cable |
No |
Suitable as computer data cable |
No |
Suitable as signalling cable |
Yes |
Certified for shipboard application |
No |
Approved type of underground installation |
Other |
Flame retardant according to IEC 60332-1-2 |
No |
Flame retardant according to IEC 60332-3-21 (Cat A F/R) |
No |
Flame retardant according to IEC 60332-3-22 (Cat A) |
No |
Flame retardant according to IEC 60332-3-23 (Cat B) |
No |
Flame retardant according to IEC 60332-3-24 (Cat C) |
No |
Flame retardant according to IEC 60332-3-25 (Cat D) |
No |
Halogen free according to IEC 60754-1 |
No |
Halogen free according to IEC 60754-3 |
No |
Circuit integrity according to IEC 60331-23 |
No |
Compatible with Grade2TV according to XP-C 90-483 |
No |
Compatible with Grade3TV according to XP-C 90-483 |
No |