Register to unlock your exclusive B2B prices and start shopping. Sign up now!
S3000 electr.swit.ins. Insert image 1

S3000 electr.swit.ins. Insert

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
68,69 €
This price is valid until 31.12.24
EAN: 4010337048299
MPN: 540500
Package: 1

Technical Information

Item condition New
Manufacture name S3000 electr.swit.ins. Insert
Brand Gira
Categories Switches
Country of origin DE
Harmonized System Code 8536 5080 00
Nominal voltage 0 V
Mounting method Flush mounted (plaster)
Colour Other
Frequency NA Hz

Packing details

Packing level 1 4010337048299
Packing level 2 4010337048299

Other Technical data

Assembly arrangement Basic element
Model Other
Surface protection Other
Rated current 0 A
Number of channels NA
Material quality Other
Type of load Other
Material Other
Type of fastening Mounting with claw and screw
Light value memory No
Substation input -
RAL-number (similar) 0
Switch capacity HVAC NA W
Applicable with movement sensor -
Applicable with transmission button -
Applicable with infrared button No
Applicable with presence indicator -
Applicable with button Yes
Applicable with time switch/timer No
Switch capacity NA W
Transparent No
IFTTT support available No
Min. depth of built-in installation box 0 mm
Compatible with Apple HomeKit No
Compatible with Google Assistant No
Compatible with Amazon Alexa No

Description

System 3000 electronic switching insert Features: Connecting auxiliary units is possible. Control of thermal servos in combination with a room temperature controller top unit. Bulb-saving switch-on. Electronic short-circuit protection. Electronic excess-temperature protection. Operation with and without neutral conductor connection. Operation with a neutral conductor: Switching of light bulbs, HV halogen lamps, electronic or inductive transformers with halogen or LED lamps, switchable or dimmable HV LED lamps or compact fluorescent lamps. Device is powered via the phase conductor and neutral conductor, therefore no leading edge or trailing edge phase control. Operation without a neutral conductor: Switching of light bulbs, HV halogen lamps, electronic or inductive transformers with halogen or LED lamps, dimmable HV LED lamps or compact fluorescent lamps. Device is powered via the the phase conductor and therefore works according to the leading edge or trailing edge principle. Automatic or manual setting of dimming principle according to load (leading or trailing edge). Display of the selected operating mode using LED. Combination with RF operating top unit, 1-gang 2-gang for KNX: Switching actuator channel, 1-gang or heating actuator, 1-gang. Sensor channel, 1-gang or 2-gang. Local control of System 3000 insert possible. Wireless control of other devices for KNX as sensor possible. Temperature detection Insert function selection for switching: NO NC operation, staircase function with switch-off pre-warning, scene function (16 scenes), blocking function, time delays. Auxiliary input can be used as an additional operating point for the System 3000 insert or for wireless control of other devices for KNX as a sensor. Insert function selection for room temperature controller: Control of 230 V servos, heating mode, cooling mode, heating and cooling mode, switchover to heating or cooling mode via communication object or auxiliary input. PWM and 2-point controller, absolute and relative setpoint setting, heating requirement control incl. cascading, valve protection function. Cyclical monitoring of the floor temperature, service mode for valve output, frost protection function (automatic or via communication object), temperature sensor calibration, boost function, summer and winter compensation, scene function (16 scenes). Auxiliary input can be used as an additional operating point for the System 3000 insert or for wireless control of other devices for KNX as a sensor. Alternatively, the auxiliary input can be parameterised for switching between heating and cooling mode. Notes : For operation without a neutral conductor, the minimum load for light bulbs, HV halogen lamps, Tronic transformers, and wound transformers increases to 50 W. If the ambient temperature is higher than 25 C, the connected load must be reduced.