Technical Information
Item condition |
New |
Manufacture name |
Safety contactor, 380 V 400 V: 55 kW, 2 N/O, 2 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals, integrated suppressor circuit in actuating ele |
Brand |
EATON
|
Categories |
Modular switches
|
Country of origin |
RO |
Harmonized System Code |
8536 4900 00
|
Modular version |
No |
Rated operation power at AC-3, 400 V |
55 kW |
Number of normally open contacts as main contact |
3 |
Number of normally closed contacts as main contact |
0 |
Number of auxiliary contacts as normally open contact |
2 |
Number of auxiliary contacts as normally closed contact |
2 |
Rated operation current Ie at AC-3, 400 V |
115 A |
Rated operation current Ie at AC-1, 400 V |
160 A |
Rated control supply voltage at AC 50 Hz |
0 V |
Rated control supply voltage at AC 60 Hz |
0 V |
Rated control supply voltage at DC |
24 V |
Type of electrical connection of main circuit |
Screw connection |
Voltage type for actuating |
DC |
Rated operation current Ie at AC-4, 400 V |
55 A |
Rated operation power at AC-4, 400 V |
28 kW |
Rated operation power NEMA |
74.6 kW |
Packing details
Packing level 1 |
4015081922314 |
Description
Safety contactor, Application: Contactors for Motors, Complete devices up to 170 A, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Screw terminals, Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging., Description: Auxiliary contact element connected non-detachably with basic device (manual activation not possible). , Rated operational current AC-3 380 V 400 V: Ie= 115 A, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 160 A, enclosed: Ith= 115 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 325 A, enclosed: Ith= 285 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 37 kW, 380 V 400 V: P= 55 kW, 660 V 690 V: P= 90 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 17 kW, 380 V 400 V: P= 28 kW, 660 V 690 V: P= 43 kW, Contacts N/O = Normally open: 2 N/O, Contacts N/C = Normally closed: 2 NC , Instructions: Contacts to EN 50 012., integrated suppressor circuit in actuating electronics, with mirror contact., Voltage AC/DC: DC operation