Register to unlock your exclusive B2B prices. Register now
Similar figure image 1

Separation amplifier 24 V AC/DC, 3-...

In stock price (excl. VAT):
177,44 €
This price is valid until 2024-09-30
Price per pcs: 177,44 €
EAN: 4047621001128
MPN: 3RS7006-1FE00
Our warehouse: No Vendor stock: No
Per pallet: N/A
Technical data
Item condition New
Manufacture name Separation amplifier 24 V AC/DC, 3-...
Brand Siemens
Categories Sensors
Country of origin DE
Harmonized System Code 8538 9091 00
Width 17.5 mm
Height 93 mm
Depth 72.5 mm
Switching current UN A
Number of channels 1
Power consumption 0.5 W
Switching power UN VA
Operating temperature -25-60 °C
Switching voltage UN V
Switching frequency UN Hz
Type of electric connection Screw connection
Degree of protection (IP) IP20
Number of output ranges +10 V ... -10 V 0
Number of output ranges +5 V ... -5 V 0
Number of output ranges 0 V ... 1 V 0
Number of output ranges 0 mA ... 10 mA 0
Number of output ranges 0 V ... 10 V UN
Number of output ranges 0 mV ... 100 mV 0
Number of output ranges 0 V ... 2 V 0
Number of output ranges 0 V ... 2.5 V 0
Number of output ranges 0 mA ... 20 mA UN
Number of output ranges 0 V ... 20 V 0
Number of output ranges 0 mV ... 200 mV 0
Number of output ranges 0 V ... 24 V 0
Number of output ranges 0 V ... 30 V 0
Number of output ranges 0 mV ... 300 mV 0
Number of output ranges 0 mA ... 5 mA 0
Number of output ranges 0 V ... 5 V 0
Number of output ranges 0 mV ... 500 mV 0
Number of output ranges 0 mV ... 60 mV 0
Number of output ranges -1 V ... +1 V 0
Number of output ranges 1 V ... 5 V 0
Number of output ranges -10 mA ... +10 mA 0
Number of output ranges -10 V ... +10 V 0
Number of output ranges 10 V ... 0 V 0
Number of output ranges 10 V ... 2 V 0
Number of output ranges -100 mV ... +100 mV 0
Number of output ranges -2 V ... +2 V 0
Number of output ranges 2 V ... 10 V 0
Number of output ranges -2.5 V ... +2.5 V 0
Number of output ranges -20 mA ... +20 mA 0
Number of output ranges -20 V ... +20 V 0
Number of output ranges 20 mA ... 0 mA 0
Number of output ranges 20 mA ... 4 mA 0
Number of output ranges -300 mV ... +300 mV 0
Number of output ranges 4 mA ... 20 mA UN
Number of output ranges -5 mA ... +5 mA 0
Number of output ranges -5 V ... +5 V 0
Number of output ranges 5 V ... 0 V 0
Number of output ranges 5 V ... 1 V 0
Number of output ranges -500 mV ... +500 mV 0
Number of output ranges -60 mV ... +60 mV 0
Number of input ranges +10 V ... -10 V 0
Number of input ranges +5 V ... -5 V 0
Number of input ranges 0 V ... 1 V UN
Number of input ranges 0 mA ... 10 mA UN
Number of input ranges 0 V ... 10 V UN
Number of input ranges 0 mV ... 100 mV UN
Number of input ranges 0 V ... 2 V UN
Number of input ranges 0 V ... 2.5 V 0
Number of input ranges 0 mA ... 20 mA UN
Number of input ranges 0 V ... 20 V UN
Number of input ranges 0 mV ... 200 mV 0
Number of input ranges 0 V ... 24 V 0
Number of input ranges 0 V ... 30 V 0
Number of input ranges 0 mV ... 300 mV UN
Number of input ranges 0 mA ... 5 mA UN
Number of input ranges 0 V ... 5 V UN
Number of input ranges 0 mV ... 500 mV UN
Number of input ranges 0 mV ... 60 mV UN
Number of input ranges -1 V ... +1 V 0
Number of input ranges 1 V ... 5 V 0
Number of input ranges -10 mA ... +10 mA 0
Number of input ranges -10 V ... +10 V 0
Number of input ranges 10 V ... 0 V 0
Number of input ranges 10 V ... 2 V 0
Number of input ranges -100 mV ... +100 mV 0
Number of input ranges -2 V ... +2 V 0
Number of input ranges 2 V ... 10 V UN
Number of input ranges -2.5 V ... +2.5 V 0
Number of input ranges -20 mA ... +20 mA UN
Number of input ranges -20 V ... +20 V 0
Number of input ranges 20 mA ... 0 mA 0
Number of input ranges 20 mA ... 4 mA 0
Number of input ranges -300 mV ... +300 mV 0
Number of input ranges 4 mA ... 20 mA UN
Number of input ranges -5 mA ... +5 mA UN
Number of input ranges -5 V ... +5 V 0
Number of input ranges 5 V ... 0 V 0
Number of input ranges 5 V ... 1 V 0
Number of input ranges -500 mV ... +500 mV 0
Number of input ranges -60 mV ... +60 mV 0
Rated operation frequency 50-60 Hz
Rated supply voltage at AC UN V
Rated supply voltage at DC UN V
Load 500 Ohm
Load influence 0 %/100%
Inherently safe according to EN 60947-5-6 NAMUR -
Galvanic separation between output to output No
Galvanic separation between input and output Yes
Galvanic separation between inputs No
Galvanic separation between supply voltage and all other current circuits Yes
Malfunction message output No
Temperature drift 0.015 %/K
SIL according to IEC 61508 None
Packing details
Packing level 1 4047621001128
Description
Separation amplifier 24 V AC/DC, 3-way separation input: 0-60 mV, 0-100 mV 0-300 mV, 0-500 mV, 0-1 V 0-2 V, 0-5 V, 0-10 mA, 0-20 V 2-10 V, 0-5 mA, 0-10 mA 0-20mA, 4-20 mA, +-5 mA, +-20 mA output: 0 - 10 V, 0/4 - 20 mA screw terminal Signal converter SIRIUS 3RS70 for galvanic isolation and for adjustable conversion of an analog standard signal or other common sensor signal between controller and sensors/actuators. Thanks to galvanic separation, the signal converters prevent mutual interference between the analog channels. Thanks to the narrow and compact design, they take up little space on the DIN rail, particularly in flat control boxes and control cabinets with small gaps between tiers The high-quality, modern design in titanium gray contributes to the integrated appearance matching all other Siemens devices in the control cabinet. The clear range of devices covers all applications and thus simplifies logistics and stock-keeping. Active and passive single-range, multi-range and universal converters are available with various supply voltages and connection types for various analog standard signals and other common sensor signals. In addition, we offer versions with manual/automatic switchover for precise specification of analog values. For the 3RS70 signal converter a matching galvanic isolation plate is available as well as various connecting combs. The 3RS70 signal converters replace the well-proven 3RS17 series. SIRIUS relays - one range for every application.